6

Technical data

Manufacturer
Address
Article number / ordering data
AS-i data
AS-i profile
Addressing
Slave address at delivery
Response time over AS-i bus
Power supply
Operating voltage
Total current consumption
General
Degree of protection
Ambient temperature
Size
Colour
Actuating force
Actuator travel
Mechanical life
Safety / Harmonized Standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
EN 954-1
EN 60947-5-1 & -5
EN ISO 13850:2008
Certificates
2TLC172094M0201, rev. B
2012-08-03
ABB AB / JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Smile 11EA AS-i: 2TLA030052R0000
Smile 11SA AS-i: 2TLA030052R0100
S-7.B.0
M12-connector
0
5 ms (+ response time of safety monitor)
30 VDC, AS-i bus. Tolerance 26.5 – 31.6 V DC.
< 60 mA
IP65
-25...+50°C
52 x 40 x 84 (+12.5 mm M12 contact) (H x W x L)
Base: Yellow
Emergency stop pushbutton (Smile 11EA AS-i): Red
Safety stop pushbutton (Smile 11SA AS-i): Black
22 ± 4 N
Approx. 4 mm to latch
> 50 000 operations
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN 954-1:1996, EN ISO 13849-1:2008/AC:2009, EN ISO 13849-2:2008,
EN 60204-1:2007+A1, EN ISO 13850:2008
-5
SIL3, PFD
: 2.95*10
, PFH
: 6.95*10
avr
d
SIL3
Performance level: PL e, category 4
MTTF
: High
d
Category 4
For E-stop button / safety stop button
For E-stop button / safety stop button
TÜV Nord (AS-i), Inspecta (emergency stop)
9
-9
www.abb.com/lowvoltage