Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS8000H
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RS8000H

  • Page 1 Edition 11/2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS8000H https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS8000H Communication Ports Technical Specifications Installation Manual Certification 11/2022 C79000-G8976-1022-07...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................4 Cabling Recommendations ..................
  • Page 5 Table of Contents Failsafe Relay Specifications ................21 Copper Ethernet Port Specifications ..............21 Fiber Optic Ethernet Port Specifications ............... 22 Operating Environment ..................22 Mechanical Specifications ..................22 Dimension Drawings ................... 23 Certification ......................... 25 Approvals ......................25 6.1.1 UKCA ........................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RS8000H is available online at https://support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS8000H Installation Manual, 11/2022, C79000-G8976-1022-07...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RS8000H provides substation hardened, fully managed, Ethernet switches specifically designed to operate reliably in electrically and environmentally harsh environments. The RUGGEDCOM RS8000H model provides IEEE 1613 Class 2 error-free communications performance under EMI stress. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RS8000H to be placed in almost any location.
  • Page 11: Description

    Introduction 1.2 Description • Exceeds IEC 61000-6-2 (generic industrial) • Exceeds NEMA TS-2 (traffic control equipment) • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) • Failsafe Output Relay: For critical failure or error alarming • Conformal coated printed circuit boards (optional) Cyber Security Features •...
  • Page 12 Introduction 1.2 Description POWER LED RESET Button Communication Ports Port Status Indicator LEDS RS232 Serial Console Port (DB9) Figure 1.1 Front and Rear Panels POWER LED Illuminates when power is being supplied to the device. Color Description Green Device ready No power RESET Button Shuts down and restarts the device.
  • Page 13: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials RS232 Serial Console Port The serial console port is for interfacing directly with the device and accessing initial management functions. For information about connecting to the device via the serial console port, refer to "Connecting to the Device" (Page 17).
  • Page 14: 1.5.1 Supported Fiber Optic Cables

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15 Introduction 1.5.1 Supported Fiber Optic Cables RUGGEDCOM RS8000H Installation Manual, 11/2022, C79000-G8976-1022-07...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Installing the Device 2.1 General Procedure NOTICE This product should be installed in a restricted access location where access can only be gained by authorized personnel who have been informed of the restrictions and any precautions that must be taken. Access must only be possible through the use of a tool, lock and key, or other means of security, and controlled by the authority responsible for the location.
  • Page 18: Mounting The Device On A Din Rail

    Installing the Device 2.2.1 Mounting the Device on a DIN Rail Note For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to "Dimension Drawings" (Page 23). 2.2.1 Mounting the Device on a DIN Rail The RUGGEDCOM RS8000H can be ordered with a panel/DIN rail adapter preinstalled on the back of the chassis.
  • Page 19: 2.2.2 Mounting The Device To A Rack

    Installing the Device 2.2.2 Mounting the Device to a Rack Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail...
  • Page 20: Mounting The Device To A Panel

    Installing the Device 2.2.3 Mounting the Device to a Panel Rack Mount Adapter Screw Figure 2.3 Rack Mounting Insert the rack mount adapter and device assembly into the rack. Note Since heat within the device is channelled to the enclosure, it is recommended that 1 rack-unit of space, or 44 mm (1.75 in), be kept empty above the device.
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.3 Connecting the Failsafe Alarm Relay Screw Panel/DIN Rail Adaptor Figure 2.4 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
  • Page 22: Connecting Power

    Installing the Device 2.4 Connecting Power Normally Closed Common Normally Open Figure 2.5 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS8000H supports a single integrated high AC/DC or low DC power supply NOTICE • For 88-300 VDC rated equipment, an appropriately rated circuit breaker must be installed.
  • Page 23 Installing the Device 2.4.1 Connecting AC Power connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing. Connect the positive wire from the power source to the positive/hot (+/H) terminal on the terminal block.
  • Page 24: 2.4.2 Connecting Dc Power

    Installing the Device 2.4.2 Connecting DC Power Stainless Steel Stud #6-32 Screw #6 Ring Tongue Figure 2.7 Chassis Ground Connection 2.4.2 Connecting DC Power To connect a high or low DC power supply to the device, do the following: NOTICE Electrical hazard – risk of damage to equipment Before testing the dielectric strength (HIPOT) in the field, remove the braided ground cable connected to the surge ground terminal and chassis ground.
  • Page 25 Installing the Device 2.4.2 Connecting DC Power Using a #6 ring tongue and #6-32 screw, secure the ground terminal on the power source to the chassis ground terminal on the device. Make sure the lug is tightened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Tongue...
  • Page 26: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM ROS console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM RS8000H Configuration Manual"...
  • Page 27: Configuring The Device

    Device Management 3.2 Configuring the Device Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM ROS interface. For more information about configuring the device, refer to the "RUGGEDCOM RS8000H Configuration Manual"...
  • Page 28: Communication Ports

    Communication Ports The RUGGEDCOM RS8000H can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM ROS. For more information on how to access the factory data file, refer to the "RUGGEDCOM RS8000H Configuration Manual"...
  • Page 29: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports The following is the pin-out for the RJ45 male connector:   Name Description Receive Data+ Receive Data- Transmit Data+ Reserved (Do Not Connect) Figure 4.2 RJ45 Ethernet Port Pin Reserved (Do Not Connect) Configuration Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Case...
  • Page 30: Technical Specifications

    Technical Specifications This chapter provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the nominal input voltage for the power supply is provided at the power source. Input Range Power Internal Fuse Maximum Power Supply Type Rating...
  • Page 31: Fiber Optic Ethernet Port Specifications

    Technical Specifications 5.4 Fiber Optic Ethernet Port Specifications Duplex FDX/HDX Cable Type > CAT-5 Wiring Standard TIA/EIA T568A/B Maximum Distance 100 m (328 ft) Isolation 1.5 kV Auto-negotiating. Shielded or unshielded. Auto-crossover and auto-polarity. Typical distance. Dependent on the number of connectors and splices. RMS 1 minute.
  • Page 32: Dimension Drawings

    Technical Specifications 5.7 Dimension Drawings Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 248.9 Figure 5.1 Overall Dimensions RUGGEDCOM RS8000H Installation Manual, 11/2022, C79000-G8976-1022-07...
  • Page 33 Technical Specifications 5.7 Dimension Drawings 479.4 464.5 Figure 5.2 Rack Mount Dimensions 274.3 264.2 Figure 5.3 Panel and Din Rail Mount Dimensions RUGGEDCOM RS8000H Installation Manual, 11/2022, C79000-G8976-1022-07...
  • Page 34: Certification

    Approvals This section details the standards to which the RUGGEDCOM RS8000H complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com]. 6.1.1 UKCA This device is certified for use in Great Britain and bears the United Kingdom Certified Assessed (UKCA) marking.
  • Page 35: European Union (Eu)

    Certification 6.1.3 European Union (EU) 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 36: Iso

    Quality management systems – Requirements 6.1.6 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: China RoHS 2 •...
  • Page 37 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Induced (Conducted) RFI Signal ports 10 V 61000-4-6 DC Power 10 V ports AC Power 10 V ports Earth 10 V ground ports Magnetic Field Enclosure 40 A/m continuous,  ...
  • Page 38 Certification 6.2 EMC and Environmental Type Tests temporary communication loss, while Class 2 requires error-free and interrupted communications. IEEE Test IEEE 1613 Description Test Levels Clause C37.90.3 Enclosure Contact ±8 kV Enclosure Air ±15 kV C37.90.2 Radiated RFI Enclosure ports 35 V/m C37.90.1 Fast Signal ports...
  • Page 39 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RS8000H Installation Manual, 11/2022, C79000-G8976-1022-07...
  • Page 40 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2022 Siemens Canada Ltd. Subject to change...