Commercial Series TriTech and TriTech AM
detectors
6

Wiring

Caution!
Apply power only after you have made and inspected all connections. Do not coil excess
!
wiring inside the motion detector.
6.1

Wiring overview

TriTech AM terminal block strip
Callout — Description
1 — Input power terminals. Voltage limits are 9 to 15 VDC. Use no smaller than 0.4 mm (26
AWG) wire pair between the detector and the power source.
2 — Alarm terminals. Solid State output. Normally closed relay rated at 25 VDC, <35 mA, 2.5
W. Do not use with capacitive or inductive loads.
3 — Tamper terminals. Normally closed switch rated at 25 VDC, <25 mA, 2.5 W.
4 — Trouble terminals. Solid State output. Normally closed relay rated at 25 VDC, <35 mA,
2.5 W. Do not use with capacitive or inductive loads.
Bosch Security Systems B.V.
2
1
NC NC
Installation manual
3
T
TR
T
RLED
Wiring | en
4
TR
2022.01 | 01 | F.01U.401.708
17