LG MULTI V 5 Engineering Manual page 12

Hide thumbs Also See for MULTI V 5:
Table of Contents

Advertisement

GENERAL DATA
Table 3: Dual Frame 208-230V Outdoor Units.
Unit Model Number
Individual Component Model Numbers
Cooling Performance
Nominal Cooling Capacity (Btu/h)
Rated Cooling Capacity (Btu/h)
Heating Performance
Nominal Heating Capacity (Btu/h)
Rated Heating Capacity (Btu/h)
Operating Range
Cooling (°F DB)
Heating (°F WB)
Synchronous — Cooling Based (°F DB)
Synchronous — Heating Based (°F WB)
Compressor
Inverter Quantity
Oil/Type
Fan (Top Discharge)
Type
Motor Output (kW) x Qty.
Motor/Drive
Operating Range (RPM)
Maximum Air Volume (CFM)
Unit Data
Refrigerant Type
Refrigerant Control/Location
Factory Charge lbs. of R410A
Max. No. Indoor Units/System
Sound Pressure dB(A)
4
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cables
5,6
Heat Exchanger
Material and Fin Coating
Rows/Fins per inch
Piping for Heat Recovery Operation
Liquid Line Connection (in., OD)
Low Pressure Vapor Line Connection (in., OD)
High Pressure Vapor Line Connection (in., OD)
Piping for Heat Pump Operation
Liquid Line Connection (in., OD)
Vapor Line Connection (in., OD)
Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of
1
refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. All capaci-
ties are net with a Combination Ratio between 95–105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF
wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Nominal heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.
2
The System Combination Ratio must be between 50–130%.
3
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4
12 | ODU PRODUCT DATA
ARUM264BTE5
22.0 Ton
ARUM096BTE5 +
ARUM168BTE5
264,000
1
252,000
2
1
297,000
2
283,000
5 to 122
-13 to +61
14 to 81
14 to 61
HSS DC Scroll x 3
PVE / FVC68D
Propeller (BLDC)
0.90 x 2 + 0.90 x 2
Cooling
0 - 1,150
Heating
80 - 1,150
22,600
R410A
EEV / Indoor Unit
23.2 + 26.5
42
3
63.0
507 + 639
534 + 666
2 x 18
2 / 17 + 3 / 17
7
3/8 & 5/8 Braze
7/8 & 1-1/8 Braze
3/4 & 7/8 Braze
7
3/8 & 5/8 Braze
7/8 & 1-1/8 Braze
©
ARUM288BTE5
24.0 Ton
ARUM096BTE5 +
ARUM192BTE5
288,000
276,000
324,000
309,000
5 to 122
-13 to +61
14 to 81
14 to 61
HSS DC Scroll x 3
PVE / FVC68D
Propeller (BLDC)
0.90 x 2 + 0.90 x 2
Brushless Digitally Controlled / Direct
0 - 1,150
80 - 1,150
22,600
R410A
EEV / Indoor Unit
23.2 + 30.9
45
63.0
507 + 659
534 + 688
2 x 18
Copper Tube / Aluminum Fin and Black Coated Fin™ / Hydrophilic
2 / 17 + 3 / 17
3/8 & 5/8 Braze
7/8 & 1-1/8 Braze
3/4 & 1-1/8 Braze
3/8 & 5/8 Braze
7/8 & 1-1/8 Braze
Communication cable between Master ODU to Slave ODU(s), and Master ODU to IDUs / HRUs to be
5
18 AWG, 2-conductor, twisted, stranded, shielded. Ensure the communication cable shield is properly
grounded to the Master ODU chassis only.
cable at any other point. Wiring must comply with all applicable local and national codes.
Power wiring is field provided, solid or stranded, and must comply with the applicable local and nation-
6
al codes. See page 20 for detailed electrical data.
LG requires that LATS software be used on all projects to ensure correct line sizing. Designer must
7
verify the shop drawing design against the as built design using LATS. Contractor must also use LG
manufactured Y-Branch and Header Kits only.
ARUM312BTE5
ARUM336BTE5
26.0 Ton
28.0 Ton
ARUM096BTE5 +
ARUM121BTE5 +
ARUM216BTE5
ARUM216BTE5
312,000
336,000
298,000
320,000
351,000
378,000
333,000
359,000
5 to 122
5 to 122
-13 to +61
-13 to +61
14 to 81
14 to 81
14 to 61
14 to 61
HSS DC Scroll x 3
HSS DC Scroll x 3
PVE / FVC68D
PVE / FVC68D
Propeller (BLDC)
Propeller (BLDC)
0.90 x 2 + 0.90 x 2
0.90 x 2 + 0.90 x 2
0 - 1,150
0 - 1,150
80 - 1,150
80 - 1,150
22,600
22,600
R410A
R410A
EEV / Indoor Unit
EEV / Indoor Unit
23.2 + 37.5
23.2 + 37.5
52
65.0
507 + 666
507 + 666
534 + 694
534 + 694
2 x 18
2 x 18
2 / 17 + 3 / 17
2 / 17 + 3 / 17
3/8 & 5/8 Braze
1/2 & 5/8 Braze
7/8 & 1-1/8 Braze
1-1/8 & 1-1/8 Braze
3/4 & 1-1/8 Braze
3/4 & 1-1/8 Braze
3/8 & 5/8 Braze
1/2 & 5/8 Braze
7/8 & 1-1/8 Braze
1-1/8 & 1-1/8 Braze
Do not ground the ODU to IDUs / HRUs communication
55
65.0

Advertisement

Table of Contents
loading

Table of Contents