Huawei PV+ESS+Charger Solution User Manual page 72

Table of Contents

Advertisement

PV+ESS+Charger Solution
User Manual
No.
Component
7
AC Charger
8
AC Charger
9
AC Charger
10
AC Charger
Issue 02 (2023-01-13)
Alarm Name
Alarm
Severity
Leakage
Critical
Detection
Circuit Fault
Contactor
Major
Fault
Temperature
Major
Sensor Faulty
Input Phase
Minor
Failure
Copyright © Huawei Technologies Co., Ltd.
Possible
Suggestion
Cause
The leakage
Step 1 Restart the charger and
detection
check whether the charger
circuit is
alarm is cleared.
faulty.
If yes, no further action is
required.
If no, replace the charger.
The
Step 1 Restart the charger and
contactor is
check whether the charger
adhered.
alarm is cleared.
If yes, no further action is
required.
If no, replace the charger.
The
Step 1 Restart the charger, wait
temperature
for 1 minute, charge the vehicle
sensor is
again, and check whether the
faulty.
fault is rectified.
If yes, no further action is
required.
If no, replace the charger.
The charging
Step 1 Check whether the input
cable is
voltage is abnormal.
incorrectly
If yes, rectify the mains input
connected.
circuit and ensure that the
voltage is normal. If the alarm
persists, go to the next step.
If no, go to the next step.
Step 2 Restart the charger, wait
for 1 minute, and check
whether the alarm is cleared.
If yes, no further action is
required.
If no, replace the charger.
5 Maintenance
66

Advertisement

Table of Contents
loading

Table of Contents