9.2.3

Removing/installing the external fan

CAUTION
Electrostatically sensitive devices
Electronic modules contain components that can be destroyed by electrostatic discharge.
These modules can be easily destroyed if they are not handled properly.
To protect your equipment against damage, follow the instructions given in the chapter ESD
Guidelines.
Qualified and trained personnel
Only qualified, trained personnel may replace and adjust an encoder.
Note
Removing/installing the encoder
Unscrew the lid of the terminal box and disconnect the power and temperature sensor cables
from the terminal box.
Unscrew the separately-driven fan (if installed) and sensor cover.
Synchronous/induction motors 1PH813