Download Print this page

HP 7502 Product End-Of-Life Disassembly Instructions page 6

Switch chassis
Hide thumbs Also See for 7502:

Advertisement

1.
Remove the three fans 10-2 from fan frame 10-1;
2.
Remove plug 10-3 from fan frame 10-1;
3.
Remove the four wire mounts 10-4 from fan frame 10-1;
4.
Unscrew the screws on PCB 10-5, and then remove PCB 10-5;
5.
Remove shielding finger 10-6 from fan frame 10-1;
6.
Unscrew the screws on handle 10-7, and then remove handle 10-7;
7.
Remove film 10-8 from fan frame 10-1.
3.2 Material of the facility built
Facility
Components
1
2
3
4
4-1
4-2
5
5-1
5-2
6
6-1
7
EL-MF877-00
Template Revision B
Figure 8 Treatments to fan module 10
Material
Weight
(g)
Fe
10411
Fe
278
ABS
22
AL
767
Complex PWB
519
Fe
1487
Complex PWB
1000
Fe
303
Complex
2600
PWB+Fe
Weight
Selective treatment for
percentage
materials and components
50.46%
1.34%
0.10%
3.71%
2.51%
The surface of PCB is
greater than 10
square centimeters
7.20%
4.84%
The surface of PCB is
greater than 10
square centimeters
1.46%
12.6%
1. Containing
brominated flame
retardants ;
2. The surface of
PCB is greater
than 10 square
centimeters;
3. Electrolyte
Details
Fe recycling
Fe recycling
Pla recycling
Al recycling
Fe recycling
Fe recycling
Fe recycling
Page 6

Advertisement

loading