Siemens RUGGEDCOM WIN5123 Installation Manual page 21

Hide thumbs Also See for RUGGEDCOM WIN5123:
Table of Contents

Advertisement

RUGGEDCOM WIN5123
Installation Guide
Figure 11: Untwisting the Wire Pairs
6.
Arrange the wires according to the following pin-out description:
Figure 12: CAT-5e PoE Cable Pin-Out
1. Pin 1
2. Pin 8
7.
Slide the wires into the loading bar and then pull the loading bar down until its face is 16 mm (0.63 in) from
the wire jacket. If necessary, use pliers to hold the wires while pulling the loading bar.
1
Figure 13:
1. Loading Bar
8.
Trim the wires until they are flush with the face of the loading bar.
9.
Insert the wires and loading bar into the plug body. Make sure:
• the cable is pushed to the front of the plug body
• the spine of the strain relief on the plug body covers the drain wire
10. Bend the strain relief until it is flat against the jacket and foil.
11. Crimp the plug and strain relief using a standard crimping tool.
Assembling the PoE Cable
2
1
2
2. Wires
3. Pin 1
4. Pin 8
Pin
Color
Number
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown