RUGGEDCOM WIN5123
Installation Guide
Section 2.6

Installing the Device in Hazardous Locations

An approved surge suppression unit is required when the base station is installed in a hazardous location.
The WIN5123 is certified for installation in Class I, Division II Groups A, B, C and D hazardous locations when
installed using the Class I, Division II kit (P/N MKIT0090). The Class I, Division II kit contains the following items:
• Lambda power supply unit (model DPP50-48)
• L-COM passive PoE injector (model BT-CAT5-P1)
• DC power cable
• AC open-ended power cable (WIN5123-AC Only)
WARNING!
EXPLOSION HAZARD
• Substitution of components may impair suitability for Class I, Division II
• Do not disconnect equipment unless power has been switched off or the area is known to be non-
hazardous
• Use only Lambda DPP50-48 Power Supply in conjunction with the unit
RISQUE D'EXPLOSION
• La substitution decomposants peut rendre ce matériel inacceptable pour les emplacements de
Classe I, Division II
• Avant de déconnecter l'equipment, couper le courant ou s'assurer que l'emplacement est désigné
non dangereux
• Utilisez l'unité uniquement avec une batterie de la marque Lamba DPP50-48
To install the base station in a hazardous location, do the following:
1.
Connect the DC power cable between the Lambda Power Supply Unit (PSU) and the L-COM passive PoE
injector.
Figure 18: Connecting the CPE in a Hazardous Location
1. Ethernet Switch
6. Lambda PSU
Installing the Device in Hazardous Locations
1
2. CAT-5e Cable
3. L-COM Passive PoE Injector
2
3
2
5
6
4. RUGGEDCOM WIN5123
Chapter 2
Installing the Device
4
5. DC Power Cable