Technical Specifications
Parameter
Ambient Relative Humidity
Ambient Storage Temperature
Section 3.4

Mechanical Specifications

Parameter
Dimensions
Weight
Enclosure
Ingress Protection
Section 3.5

IDU to ODU Cable Specifications

Special 4×2×24 AWG FTP Cat. 5e Outdoor Double Jacket Data Cable UL (1581 VW 1)
IDU to ODU Cable
Applications:
General Construction:
Conductor Size:
Outer Jacket Material:
Outer Diameter:
Weight:
IDU to ODU Cable Design and Materials
Conductor Material:
Conductor Size:
Insulation Material:
Insulation O.D.:
Color Code:
24
Range
Comments
5% to 95%
Non-condensing
-40 to 75 °C
(-40 to 167 °F)
Refer to
Outdoor installations, fixed or portable installations, digital distribution frames in
transmission stations, outdoor installations in harsh environments.
Custom made cable designed specially for wireless systems, meeting the requirements of
Cat. 5e per ANSI/TIA/EIA-568-B.2 and IEC 61156-5. The cable contains 4 twisted pairs,
cabled, foil-tape shielded and jacketed with two special black UV resistant, flame retardant
PVC compounds for direct outdoor use in harsh electrical environments. The diameter of the
inner core complies with RJ45 connecting hardware allowing direct connection to equipment
without patch cords.
0.52 mm
UV resistant FR-PVC
7.9 mm nominal
68.0 kg/km
Bare copper
24 AWG
Solid PO
1.07 mm
Per TIA/EIA 568-B