6-3. EHSC-MECR2.UK, EHSD-MECR2.UK, EHSD-MCR2.UK, ERSC-MECR2.UK
EHSC-MECR3.UK, EHSD-MECR3.UK, EHSD-MCR3.UK, ERSC-MECR3.UK
CNPWM
(WH)
1
3
3
CNP1
TBO.1
(WH)
1
M
1
1~
2
3
M
MP1
3
1~
M
2WV2b
1~
4
MP2
5
M
6
1~
MP3
X14
1
M
1~
3
MP4
CNP4
(RD)
TBO.2
X5A
Close
1
M
N
Open
1~
2
X5B
3
MXV
1
4
3
*1
5
5
6
CNV1
(WH)
TBO.3
X10
1
Signal output
(Boiler)
2
X11
Signal output
3
(Error)
4
X12
Signal output
5
(Defrost)
6
X15
Signal output
7
(Comp. ON)
8
TBO.4
X13
1
CNIH
M
(OG)
2
X9
2WV2a
3
1
4
3
X8
5
Signal output
(Cooling)
6
1
3
CNBHT
(BK)
CNBC
(GY)
1
3
X6
1
3
X7
5
7
CNBH
(WH)
Table 1 Signal Inputs
Name Terminal block Connector
Item
IN1
TBI.1 13-14
Room thermostat 1 input *1 Refer to SW2-1 in <6-16. DIP switch functions>.
IN2
TBI.1 11-12
Flow switch 1 input
IN3
TBI.1 9-10
Flow switch 2 input (Zone1) Refer to SW3-2 in <6-16. DIP switch functions>.
IN4
TBI.1 7-8
Demand control input
IN5
TBI.1 5-6
Outdoor thermostat input *2 Standard operation Heater operation/ Boiler operation *3
IN6
TBI.1 3-4
Room thermostat 2 input *1 Refer to SW3-1 in <6-16. DIP switch functions>.
IN7
TBI.1 1-2
Flow switch 3 input (Zone2) Refer to SW3-3 in <6-16. DIP switch functions>.
IN8
TBI.3 1-2
Electric energy meter 1
IN9
TBI.3 3-4
Electric energy meter 2
IN10
TBI.3 5-6
Heat meter
IN11
TBI.3 7-8
Smart grid ready input
IN12
TBI.3 9-10
IN1A TBI.3 12-14 CN1A Flow sensor
*1. Set the ON/OFF cycle time of the room thermostat for 10 minutes or more; otherwise the compressor may be
damaged.
*2. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may
be reduced.
*3. To turn on the boiler operation, use the main remote controller to select "Boiler" in "External input setting" screen
in the service menu.
Table 2 Outputs
Name Terminal block Connector
OUT1
TBO.1 1-2 CNP1 Water circulation pump 1 output (Space heating/cooling & DHW)
OUT2
TBO.1 3-4
Water circulation pump 2 output (Space heating/cooling for Zone1)
Water circulation pump 3 output (Space heating/cooling for Zone2) *1
OUT3
TBO.1 5-6
2-way valve 2b output *2
OUT4
TBO.2 4-6 CNV1 3-way valve (2-way valve) output
TBO.2 1-2
OUT5
Mixing valve output *1
TBO.2 2-3
OUT6
CNBH 1-3 Booster heater 1 output
OUT7
CNBH 5-7 Booster heater 2 output
OUT8
TBO.4 5-6
Cooling signal output
OUT9
TBO.4 3-4 CNIH Immersion heater output
OUT10 TBO.3 1-2
Boiler output
OUT11 TBO.3 3-4
Error output
OUT12 TBO.3 5-6
Defrost output
OUT13 TBO.4 1-2
2-way valve 2a output *2
OUT14
CNP4 Water circulation pump 4 output (DHW)
OUT15 TBO.3 7-8
Comp. ON signal
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
OCH571D
<How to use TBO.1 to 4>
1
Connect them using either way as shown below.
2
4
F1
6
Tool
CN01
F2
(WH)
Conductor
X1
Outline view
X2
X3
1
TBO.1
2
3
CNP1
1
(WH)
4
3
5
6
IEC T6.3AL250V
1
1
CNP4
1
TBO.2
3
(RD)
2
SW5
3
4
5
8
LED1
6
1
1
X4
CNV1
TBO.3
3
1
SW4
(WH)
2
5
6
3
1
4
5
SW3
6
LED2
7
8
8
1
TBO.4
1
LED3
2
SW2
3
4
8
5
1
1
6
CNIH
(OG)
3
SW1
1
1
CNBC
CNBHT
8
(GY)
(BK)
3
3
1
LED4
CNBH
(WH)
7
CN1A
CNW5
(WH)
(WH)
1
1
2
4
2 4 6 8 10 12 14
2 4 6 8 10 12 14
1 3 5 7 9 11 13
1 3 5 7 9 11 13
1
TBI.1
TBI.3
TBI.1
1
2
3
4
5
6
7
1
2
1
4
1
3
1
2
t
t
t
t
t
°
°
°
°
°
OFF (Open)
Refer to SW2-2 in <6-16. DIP switch functions>.
Normal
Heat source OFF/ Boiler operation *3
Refer to installation manual.
Item
Indoor unit powered
via outdoor unit
To outdoor
Power supply
unit
~/N 230V 50Hz
Tool
L
N
S1
S2
S3
TB1
Conductor
Top view
BK
1
BK
2
CN01
(WH)
4
6
1
2
CN01
CN01
(WH)
4
(WH)
F2
F1
6
IEC T10AL250V
1
CN3C
BN
(BU)
1
3
CN3C
CN3C
OG
(BU)
(BU)
3
1
CNPWM
(WH)
3
CNRF
Wireless receiver
(WH)
(Option)
CN105
WiFi adapter
(Option)
(RD)
CNIT
(BU)
1
CN22
(BU)
2
CN108
CNW12
CN21
CN20
*1
(RD)
(YE)
(RD)
1
1
1
3WV
2WV1
3
2
4
4 5 6
4 5 6
TBO.2
TBO.2
2
4
6
8
10
12
M
M
3
5
7
9
11
13
1~
1~
TBI.2
3WV
2WV1
TBI.3
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
+
+
+
CN22
CN1A
(BU)
(WH)
1
4
1
ON (Short)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Heating
DHW
Close
Stop
Open
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Normal
Error
Normal Defrost
OFF
ON
OFF
ON
OFF
ON
16
Indoor unit powered
by independent source
To outdoor
unit
L
N
S1
S2
S3
TB1
BK
BK
1
2
4
6
BN
1
OG
3
1. Symbols used in wiring diagram are,
connector,
: terminal block.
2. Indoor unit and outdoor unit connecting wires have
polarities, make sure to match terminal numbers (S1,
S2, S3) for correct wirings.
3. Since the outdoor unit side electric wiring may change,
be sure to check the outdoor unit electric wiring diagram
for service.
2
3
4
5
6
7
8
9
10
11
12
13
14
2
t
°
t
°
t
°
t
°
t
°
t
°
Symbol
Name
TB1
Terminal block <Power supply, Outdoor unit>
MP1
Water circulation pump 1
(Space heating/cooling & DHW)
MP2
Water circulation pump 2
(Space heating/cooling for Zone1)(Local supply)
MP3
Water circulation pump 3
(Space heating/cooling for Zone2)(Local supply)
MP4
Water circulation pump 4 (DHW)(Local supply)
3WV(2WV1) 3-way valve (2-way valve 1)(Local supply)
2WV2a
2-way valve (For Zone 1)(Local supply)
2WV2b
2-way valve (For Zone 2)(Local supply)
MXV
Mixing valve (Local supply)
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)(Option)
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
THW8
Thermistor (Zone2 flow temp.)(Option)
THW9
Thermistor (Zone2 return temp.)(Option)
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
IN3
Flow switch 2 (Local supply)
IN4
Demand control (Local supply)
IN5
Outdoor thermostat (Local supply)
IN6
Room thermostat 2 (Local supply)
IN7
Flow switch 3 (Local supply)
IN8
Electric energy meter 1 (Local supply)
IN9
Electric energy meter 2 (Local supply)
IN10
Heat meter (Local supply)
IN11
Smart grid ready input (Local supply)
IN12
IN1A
Flow sensor
FLOW TEMP. CONTROLLER (FTC5)
TBO.1−4 Terminal block <Outputs>
TBI.1−3 Terminal block <Signal Inputs, Thermistor>
F1
Fuse (IEC T10AL250V)
F2
Fuse (IEC T6.3AL250V)
SW1−5 DIP switch *See <6-16. DIP switch functions>.
X1−15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main remote controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
: