Mitsubishi Electric EHSC-MEC Service Manual page 27

Hide thumbs Also See for EHSC-MEC:
Table of Contents

Advertisement

6-14. EHSC-TM9CR1.UK
Power supply
to Booster heater
3~ 230V 50Hz
L1
L2
L3
(1)
(3)
(5)
ECB1
2 4 6
1
3
5
A1
BHCP
2
4
6
A2
BHC1
1
3
5
1
3
5
BHC2
A1
A1
A2
2
4
6
A2
2
4
6
2
2
2
BH1
BH2
BHF
BHT
2
2
2
2
2
1. Symbols used in wiring diagram are,
connector,
: terminal block.
2. Indoor unit and outdoor unit connecting wires
have polarities, make sure to match terminal
numbers (S1, S2, S3) for correct wirings.
3. Since the outdoor unit side electric wiring may
change, be sure to check the outdoor unit
electric wiring diagram for service.
Table 1 Signal Inputs
Name Terminal block Connector
Item
Room thermostat
IN1
TBI.1 13-14
1 input
Flow switch 1
IN2
TBI.1 11-12
input
Flow switch 2
IN3
TBI.1 9-10
input (Zone1)
Demand control
IN4
TBI.1 7-8
input
Outdoor thermo-
IN5
TBI.1 5-6
stat input *1
Room thermostat
IN6
TBI.1 3-4
2 input
Flow switch 3
IN7
TBI.1 1-2
input (Zone2)
Electric energy
IN8
TBI.3 1-2
meter 1
Electric energy
IN9
TBI.3 3-4
meter 2
IN10
TBI.3 5-6
Heat meter
IN1A TBI.3 12-14 CN1A Flow sensor
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the
heaters and related parts may be reduced.
*2. To turn on the boiler operation, use the main remote controller to select "Boiler" in
"External input setting" screen in the service menu.
Symbol
Name
TB1
Terminal block <Power supply, Outdoor unit>
ECB1
Earth leakage circuit breaker for booster heater
MP1
Water circulation pump 1(Space heating & DHW)
MP2
Water circulation pump 2
(Space heating for Zone1)(Local supply)
MP3
Water circulation pump 3
(Space heating for Zone2)(Local supply)
MP4
Water circulation pump 4 (DHW)(Local supply)
3WV(2WV1) 3-way valve (2-way valve 1)(Local supply)
2WV2a
2-way valve (For Zone 1)(Local supply)
2WV2b
2-way valve (For Zone 2)(Local supply)
MXV
Mixing valve (Local supply)
BHT
Thermostat for booster heater
BHF
Thermal fuse for booster heater
BH1
Booster heater 1
BH2
Booster heater 2
BHC1
Contactor for booster heater 1
BHC2
Contactor for booster heater 2
BHCP
Contactor for booster heater protection
OCH571D
CNPWM
(WH)
1
3
3
CNP1
TBO.1
(WH)
1
X1
1
M
1~
2
3
M
MP1
X2
3
1~
M
2WV2b
1~
4
MP2
X3
5
M
6
1~
MP3
X14
1
M
1~
3
MP4
CNP4
(RD)
TBO.2
X5A
Close
1
M
N
1~
Open
2
X5B
MXV
3
X4
1
4
3
*1
5
5
6
CNV1
(WH)
TBO.3
X10
1
Signal output
(Boiler)
2
X11
Signal output
3
(Error)
4
X12
5
Signal output
(Defrost)
6
X15
7
Signal output
(Comp. ON)
8
TBO.4
X13
1
CNIH
1
M
(OG)
CNBHT
2
3
X9
(BK)
2WV2a
3
1
1
4
CNBC
3
X8
3
(GY)
5
Signal output
(Cooling)
6
1
3
CNBH
5
(WH)
1
7
3
CNBHT
(BK)
CNBC
(GY)
1
3
X6
1
:
3
X7
5
7
CNBH
(WH)
OFF (Open)
ON (Short)
Refer to SW2-1 in
<6-16. DIP switch functions>.
Refer to SW2-2 in
<6-16. DIP switch functions>.
Refer to SW3-2 in
<6-16. DIP switch functions>.
Heat source OFF/
Normal
Boiler operation *2
Standard opera-
Heater operation/
tion
Boiler operation *2
Refer to SW3-1 in
<6-16. DIP switch functions>.
Refer to SW3-3 in
<6-16. DIP switch functions>.
Refer to installation manual.
Symbol
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)(Option)
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
THW8
Thermistor (Zone2 flow temp.)(Option)
THW9
Thermistor (Zone2 return temp.)(Option)
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
IN3
Flow switch 2 (Local supply)
IN4
Demand control (Local supply)
IN5
Outdoor thermostat (Local supply)
IN6
Room thermostat 2 (Local supply)
IN7
Flow switch 3 (Local supply)
1
<How to use TBO.1 to 4>
2
Connect them using either way as shown below.
4
F1
6
Tool
CN01
F2
(WH)
Conductor
Outline view
Top view
1
TBO.1
2
3
1
CNP1
(WH)
4
3
5
6
F2
IEC T6.3AL250V
1
1
CNP4
TBO.2
1
(RD)
3
2
3
SW5
4
5
8
LED1
6
1
1
CNV1
TBO.3
3
1
SW4
(WH)
2
5
6
3
1
4
5
SW3
6
LED2
7
8
8
1
TBO.4
1
LED3
2
SW2
3
4
8
5
1
1
6
CNIH
3
(OG)
SW1
1
1
CNBC
CNBHT
8
(GY)
(BK)
3
3
1
LED4
CNBH
(WH)
7
CN1A
CNW5
CNW12
(WH)
(WH)
(RD)
1
1
1
2
4
4
2 4 6 8 10 12 14
2 4 6 8 10 12 14
2
4
6
1 3 5 7 9 11 13
1 3 5 7 9 11 13
1
3
5
7
TBI.3
TBI.2
TBI.1
TBI.1
1
2
3
4
5
6
7
8
9
10
1
2
1
4
1
3
1
2
t
°
t
°
t
°
t
°
t
°
Table 2 Outputs
Name Terminal block Connector
Water circulation pump 1 output (Space heating/cooling
OUT1
TBO.1 1-2 CNP1
& DHW)
Water circulation pump 2 output (Space heating/cooling
OUT2
TBO.1 3-4
for Zone1)
Water circulation pump 3 output (Space heating/cooling
for Zone2) *1
OUT3
TBO.1 5-6
2-way valve 2b output *2
OUT4
TBO.2 4-6 CNV1 3-way valve (2-way valve) output
TBO.2 1-2
OUT5
Mixing valve output *1
TBO.2 2-3
OUT6
CNBH 1-3 Booster heater 1 output
OUT7
CNBH 5-7 Booster heater 2 output
OUT8
TBO.4 5-6
Cooling signal output
OUT9
TBO.4 3-4 CNIH Immersion heater output
OUT10 TBO.3 1-2
Boiler output
OUT11 TBO.3 3-4
Error output
OUT12 TBO.3 5-6
Defrost output
OUT13 TBO.4 1-2
2-way valve 2a output *2
OUT14
CNP4 Water circulation pump 4 output (DHW)
OUT15 TBO.3 7-8
Comp. ON signal
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
Name
27
Indoor unit powered
Indoor unit powered
by independent source
via outdoor unit
To outdoor
Power supply
unit
~/N 230V 50Hz
Tool
L
N
S1
S2
S3
TB1
L
N
Conductor
BK
1
BK
BK
2
CN01
BK
(WH)
4
1
6
1
2
CN01
CN01
2
(WH)
4
(WH)
4
F1
6
6
IEC T10AL250V
1
CN3C
BN
(BU)
1
1
3
CN3C
CN3C
OG
(BU)
(BU)
3
3
1
CNPWM
(WH)
3
CNRF
Wireless receiver
(WH)
(Option)
WiFi adapter
CN105
(Option)
(RD)
CNIT
(BU)
1
CN22
(BU)
2
CN108
CN21
CN20
*1
(YE)
(RD)
1
1
2WV1
3WV
2
3
4 5 6
4 5 6
TBO.2
TBO.2
8
10
12
M
M
9
11
13
1~
1~
3WV
2WV1
TBI.3
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
+
+
+
CN22
CN1A
(BU)
(WH)
1
4
1
2
t
°
Item
Symbol
Name
IN8
Electric energy meter 1 (Local supply)
IN9
Electric energy meter 2 (Local supply)
IN10
Heat meter (Local supply)
IN1A
Flow sensor
FLOW TEMP. CONTROLLER (FTC5)
TBO.1−4 Terminal block <Outputs>
TBI.1−3 Terminal block <Signal Inputs, Thermistor>
F1
Fuse (IEC T10AL250V)
F2
Fuse (IEC T6.3AL250V)
SW1−5 DIP switch *See <6-16. DIP switch functions>.
X1−15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main remote controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
To outdoor
unit
S1
S2
S3
TB1
BN
OG
5
6
7
8
9
10
11
12
13
14
t
°
t
°
t
°
t
°
t
°
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Heating
DHW
Close
Stop
Open
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Normal
Error
Normal Defrost
OFF
ON
OFF
ON
OFF
ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents