Mitsubishi Electric EHSC-MEC Service Manual page 22

Hide thumbs Also See for EHSC-MEC:
Table of Contents

Advertisement

6-9. EHSC-VM6CR2.UK, EHSC-VM6ECR2.UK, EHPX-VM6CR2.UK
EHSC-VM6CR3.UK, EHSC-VM6ECR3.UK, EHPX-VM6CR3.UK
Power supply
to Booster heater
~/N 230V 50Hz
L
N
(1)
(3)
ECB1
2 4
1
3
5
A1
BHCP
A2
2
4
6
BHC1
1
3
5
1
3
5
BHC2
A1
A1
A2
A2
2
4
6
2
4
6
BH1
BH2
2
2
2
BHF
BHT
2
2
1
CNBHT
3
(BK)
1
2
CNBC
3
(GY)
1
2
3
CNBH
2
5
(WH)
7
Table 1 Signal Inputs
Name Terminal block Connector
Item
IN1
TBI.1 13-14
Room thermostat 1 input *1 Refer to SW2-1 in <6-16. DIP switch functions>.
IN2
TBI.1 11-12
Flow switch 1 input
IN3
TBI.1 9-10
Flow switch 2 input (Zone1) Refer to SW3-2 in <6-16. DIP switch functions>.
IN4
TBI.1 7-8
Demand control input
IN5
TBI.1 5-6
Outdoor thermostat input *2 Standard operation Heater operation/ Boiler operation *3
IN6
TBI.1 3-4
Room thermostat 2 input *1 Refer to SW3-1 in <6-16. DIP switch functions>.
IN7
TBI.1 1-2
Flow switch 3 input (Zone2) Refer to SW3-3 in <6-16. DIP switch functions>.
IN8
TBI.3 1-2
Electric energy meter 1
IN9
TBI.3 3-4
Electric energy meter 2
IN10
TBI.3 5-6
Heat meter
IN11
TBI.3 7-8
Smart grid ready input
IN12
TBI.3 9-10
IN1A TBI.3 12-14 CN1A Flow sensor
*1. Set the ON/OFF cycle time of the room thermostat for 10 minutes or more; otherwise the compressor may be
damaged.
*2. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts
may be reduced.
*3. To turn on the boiler operation, use the main remote controller to select "Boiler" in "External input setting"
screen in the service menu.
Table 2 Outputs
Name Terminal block Connector
OUT1
TBO.1 1-2 CNP1 Water circulation pump 1 output (Space heating/cooling & DHW)
OUT2
TBO.1 3-4
Water circulation pump 2 output (Space heating/cooling for Zone1)
Water circulation pump 3 output (Space heating/cooling for Zone2) *1
OUT3
TBO.1 5-6
2-way valve 2b output *2
OUT4
TBO.2 4-6 CNV1 3-way valve (2-way valve) output
TBO.2 1-2
OUT5
Mixing valve output *1
TBO.2 2-3
OUT6
CNBH 1-3 Booster heater 1 output
OUT7
CNBH 5-7 Booster heater 2 output
OUT8
TBO.4 5-6
Cooling signal output
OUT9
TBO.4 3-4 CNIH Immersion heater output
OUT10 TBO.3 1-2
Boiler output
OUT11 TBO.3 3-4
Error output
OUT12 TBO.3 5-6
Defrost output
OUT13 TBO.4 1-2
2-way valve 2a output *2
OUT14
CNP4 Water circulation pump 4 output (DHW)
OUT15 TBO.3 7-8
Comp. ON signal
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
OCH571D
1
2
4
F1
CNPWM
6
(WH)
1
CN01
3
F2
(WH)
3
CNP1
(WH)
TBO.1
X1
1
1
M
1~
2
MP1
3
M
X2
3
1~
M
2WV2b
1~
4
MP2
X3
5
M
1
TBO.1
1~
6
2
MP3
X14
1
3
1
CNP1
M
(WH)
4
3
1~
5
MP4
3
6
CNP4
(RD)
1
TBO.2
CNP4
1
(RD)
3
2
TBO.2
X5A
3
Close
1
4
M
N
1~
Open
2
5
X5B
6
MXV
3
1
X4
CNV1
1
4
TBO.3
3
1
(WH)
3
*1
5
5
2
5
3
6
CNV1
4
(WH)
5
6
TBO.3
7
X10
1
Signal output
8
(Boiler)
2
X11
TBO.4
1
3
Signal output
2
(Error)
4
3
X12
5
4
Signal output
(Defrost)
5
6
X15
6
1
CNIH
Signal output
7
(OG)
3
(Comp. ON)
8
TBO.4
1
1
CNBC
CNBHT
X13
1
CNIH
(GY)
(BK)
M
3
3
(OG)
2
2WV2a
X9
3
1
1
4
3
CNBH
X8
5
Signal output
(WH)
(Cooling)
6
7
1
3
CNBHT
(BK)
CNBC
(GY)
2 4 6 8 10 12 14
1
1 3 5 7 9 11 13
3
X6
TBI.1
1
3
X7
5
7
CNBH
(WH)
1
2
1
4
1
t
t
t
t
°
°
°
°
OFF (Open)
Refer to SW2-2 in <6-16. DIP switch functions>.
Normal
Heat source OFF/ Boiler operation *3
Refer to installation manual.
Item
Indoor unit powered
via outdoor unit
To outdoor
unit
<How to use TBO.1 to 4>
Connect them using either way as shown below.
Tool
Tool
L
N
S1
S2
Conductor
Conductor
Outline view
Top view
BK
1
BK
2
CN01
(WH)
4
1
6
2
CN01
(WH)
4
F2
F1
6
IEC T6.3AL250V
IEC T10AL250V
1
SW5
1
CN3C
BN
(BU)
1
3
CN3C
8
LED1
OG
(BU)
1
3
1
CNPWM
SW4
(WH)
3
6
1
CNRF
Wireless receiver
(WH)
(Option)
SW3
LED2
8
1
WiFi adapter
CN105
(Option)
(RD)
LED3
SW2
8
CNIT
1
(BU)
SW1
1
CN22
(BU)
2
8
CN108
LED4
CN1A
CNW5
CNW12
CN21
CN20
(WH)
(WH)
(RD)
(YE)
(RD)
*1
1
1
1
1
1
3WV
2
2
3
4
4
4 5 6
TBO.2
2 4 6 8 10 12 14
2
4
6
8
10
12
M
1 3 5 7 9 11 13
1
3
5
7
9
11
13
1~
TBI.2
TBI.3
3WV
TBI.3
TBI.1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
+
+
+
3
1
2
t
°
ON (Short)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Heating
DHW
Close
Stop
Open
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Normal
Error
Normal Defrost
OFF
ON
OFF
ON
OFF
ON
22
Indoor unit powered
by independent source
Power supply
To outdoor
unit
~/N 230V 50Hz
S3
TB1
L
N
S1
S2
S3
TB1
BK
BK
1
2
CN01
(WH)
4
6
BN
1
CN3C
OG
(BU)
3
1. Symbols used in wiring diagram are,
connector,
: terminal block.
2. Indoor unit and outdoor unit connecting wires have
polarities, make sure to match terminal numbers (S1,
S2, S3) for correct wirings.
3. Since the outdoor unit side electric wiring may
change, be sure to check the outdoor unit electric
wiring diagram for service.
2WV1
4 5 6
TBO.2
M
1~
2WV1
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
CN22
CN1A
(BU)
(WH)
1
4
1
2
t
°
t
°
t
°
t
°
t
°
t
°
Symbol
Name
TB1
Terminal block <Power supply, Outdoor unit>
ECB1
Earth leakage circuit breaker for booster heater
MP1
Water circulation pump 1(Space heating & DHW)
MP2
Water circulation pump 2
(Space heating for Zone1)(Local supply)
MP3
Water circulation pump 3
(Space heating for Zone2)(Local supply)
MP4
Water circulation pump 4 (DHW)(Local supply)
3WV(2WV1) 3-way valve (2-way valve 1)(Local supply)
2WV2a
2-way valve (For Zone 1)(Local supply)
2WV2b
2-way valve (For Zone 2)(Local supply)
MXV
Mixing valve (Local supply)
BHT
Thermostat for booster heater
BHF
Thermal fuse for booster heater
BH1
Booster heater 1
BH2
Booster heater 2
BHC1
Contactor for booster heater 1
BHC2
Contactor for booster heater 2
BHCP
Contactor for booster heater protection
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)(Option)
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
THW8
Thermistor (Zone2 flow temp.)(Option)
THW9
Thermistor (Zone2 return temp.)(Option)
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
IN3
Flow switch 2 (Local supply)
IN4
Demand control (Local supply)
IN5
Outdoor thermostat (Local supply)
IN6
Room thermostat 2 (Local supply)
IN7
Flow switch 3 (Local supply)
IN8
Electric energy meter 1 (Local supply)
IN9
Electric energy meter 2 (Local supply)
IN10
Heat meter (Local supply)
IN11
Smart grid ready input (Local supply)
IN12
IN1A
Flow sensor
FLOW TEMP. CONTROLLER (FTC5)
TBO.1−4 Terminal block <Outputs>
TBI.1−3 Terminal block <Signal Inputs, Thermistor>
F1
Fuse (IEC T10AL250V)
F2
Fuse (IEC T6.3AL250V)
SW1−5 DIP switch *See <6-16. DIP switch functions>.
X1−15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main remote controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
: