5.9. Remote sensor (optional parts)

For the installation method, please refer to the installation manual of the Remote sensor.
• Remove the existing connector and replace it with the remote sensor connector (ensure that
the correct connector is used).
• The original connector should be insulated to ensure that it does not come into contact with
other electrical circuitry.
• Use conduit hole when external output cable is used.
To protect the cable insulation after opening a knockout hole, remove any burrs from the
edge of the hole.
Setting for room temperature correction
When a Remote sensor is connected, set the function setting of indoor unit as indicated
below.
• Function number "30":
Set the setting number to "00". (Default)
• Function number "31":
Set the setting number to "02".
* Refer to "6.3. Function setting" for details about function number and setting number

5.10. IR receiver unit (optional parts)

For the installation method, please refer to the installation manual of IR receiver unit.
• Use 7 pins for receiver unit cable.
• At first, connect the receiver unit cable to the controller PCB.
• Attach the core that comes between controller PCB and the clamp.
• Use conduit hole when external output cable is used.
To protect the cable insulation after opening a knockout hole, remove any burrs from the
edge of the hole.

6. FIELD SETTING

There are 3 methods for address setting by field setting as follows.
Please set by either of the methods.
Each setting method is described in below (1) to (3).
(1) IU AD, REF AD SW settings: This section (refer to "6.1. Setting the address")
(2) Remote controller settings:
Refer to the wired or wireless remote controller manual for
detailed setting information. (Set IU AD, REF AD SW to 0)
(3) Automatic address settings: Refer to the outdoor unit manual for detailed setting
information. (Set IU AD, REF AD SW to 0)
Be sure to turn off the power before performing the field setting.
Do not operate any switches other than prescribed, as it can cause the unit to operate
improperly or malfunction.
Use an insulated screwdriver to set the DIP switches.

6.1. Setting the address

Manual address setting method
If the receiver unit is attached, the indoor unit address and the refrigerant system address
can also be set up through the wireless remote controller.
For indoor
CAUTION
unit address
Use an insulated
screwdriver to set the DIP
switches.
Indoor unit
• Rotary switch (IU AD × 1)...Factory setting "0"
address
• Rotary switch (IU AD × 10)...Factory setting "0"
When connecting multiple indoor units to 1 refrigerant system, set the
address at IU AD SW as shown in the table A.
Refrigerant sys-
• Rotary switch (REF AD × 1)...Factory setting "0"
tem address
• Rotary switch (REF AD × 10)...Factory setting "0"
In the case of multiple refrigerant systems, set REF AD SW as shown in
the table A for each refrigerant system.
Set to the same refrigerant system address as the outdoor unit.
En-17
CAUTION
CAUTION
CAUTION
For refrigerant
system address
IU AD
REF AD
RC AD
×10
×1
×10
×1
SET3
SET4
• If working in an environ-
Table A
ment where the wireless
remote controller can
Address
be used, the addresses
can also be set using the
Refrigerant
remote controller.
system
• If setting the addresses
using the wireless remote
0
controller, set the indoor
1
unit address and refriger-
ant system address to "00".
2
(For information on setting
3
using the wireless remote
4
controller.)
5
* Do not set the indoor unit
address (IU AD SW) at
64 to 99.
10
It may result in failure.
11
99
Setting example
Setting
Setting range
Indoor unit address
0 to 63
Refrigerant system
0 to 99
address

6.2. Custom code setting

• Selecting the custom code prevents the indoor unit mix-up. (Figure below)
(Up to 4 codes can be set.)
• Perform the setting for both the indoor unit and the remote controller.
Confusion
Indoor
unit
Remote
controller
Setting method
Set the DIP switch
Dip switch "SET 3"
SET 3 SW1, SW2,
ON
referring to the fol-
lowing table.
OFF
A (factory setting)
DIP switch SET3 SW1
DIP switch SET3 SW2

6.3. Function setting

• Function setting can be performed with the wired or wireless remote controller.
(The remote controller is optional equipment)
• Refer to the wired or wireless remote controller manual for detailed setting information. (Set
IU AD, REF AD SW to 0)
• Refer to "6.1. Setting the address" for indoor unit address and refrigerant system address
settings.
• Turn the power of the indoor unit on before starting the setting.
* Turning on the power to the indoor units initializes EEV, so make sure the piping air tight
test and vacuuming have been conducted before turning on the power.
* Also check again to make sure no wiring mistakes were made before turning on the power.
Rotary switch
Rotary switch
Address
setting
REF AD SW
Indoor unit
× 10
× 1
× 10
0
0
0
0
1
1
0
2
2
0
3
3
0
4
4
0
5
5
1
0
10
1
1
11
9
9
63
Type of switch
Setting
example 2
IU AD × 10
IU AD × 1
Setting
example 63
REF AD × 10 REF AD × 1
Code change
A
B
C
A
B
C
IU AD
REF AD
×10
×1
×10
×1
SET3
SET4
Custom code
B
C
OFF
ON
OFF
OFF
OFF
ON
setting
IU AD SW
× 1
0
0
0
1
0
2
0
3
0
4
0
5
1
0
1
1
6
3
D
D
RC AD
D
ON
ON