Specifications

BEVPC
Indoor unit
Model name
Outdoor unit
Refrigerant
Total Refrigerant Amount (g)
GWP
CO2 equivalent (tonnes)
Anti-Electric
Climate Class
Heating Type
Power Supply Connection
Pdesign C (kW)
Pdesign H (kW)
SEER/AEER/Weight EER (W/W)
SCOP/ACOP/Weight EER (W/W)
Energy Level-Cooling
Energy Level-Heating
Annual Energy Consumption-
Cooling (kWh)
Annual Energy Consumption-
Heating (kWh)
The declared capacity for calculation
of SCOP at reference
condition (kW)
The back up heating capacity
assumed for calculation of SCOP at
reference design condition (kW)
Power of Electric Heater (W)
Cooling Power Input (W)
Heating Power Input (W)
Voltage/Frequency (V/Hz)
Cooling Running Current (A)
40 /
87
EN
BEVPC 090
BEVPC 091
R32
570
675
0.385
Class I
T1
Heat Pump
Indoor
2.5
2.1 (Average
Season)
6.1
4.0(Average Season)
A++ (EU)
A+ (Average
Season)
144
735
design
1.8(Average Season) 2.2(Average Season) 3.5(Average Season)
0.3(Average Season) 0.3(Average Season) 0.6(Average Season)
/
750
680
1Ph~/220-240V/50Hz 1Ph~/220-240V/50Hz
3.5
BEVPC 120
BEVPC 180
BEVPC 121
BEVPC 181
R32
580
1070
675
0.392
0.722
Class I
Class I
T1
Heat Pump
Heat Pump
Indoor
Intdoor
3.2
5.1
2.4 (Average
4.1 (Average
Season)
Season)
6.1
6.1
4.0 (Average
4.0 (Average
Season)
Season)
A++ (EU)
A++ (EU)
A+ (Average
A+ (Average
Season)
Season)
184
293
875
1435
/
1190
1690
950
1460
1Ph~/220-240V/50Hz
5.5
Air-conditioners / User's Manual
R32
675
T1
/
7.8

Advertisement