ABB 6310408P Product Manual
ABB 6310408P Product Manual

ABB 6310408P Product Manual

Maintenance bypass panel for 827e inverter plant

Advertisement

Quick Links

PRODUCT MANUAL
Maintenance Bypass Panel For 827E Inverter
Plant
6310408P
6310408P-1
Page 1
© Copyright 2023 ABB. All rights reserved.
827E MBS_MAN
Rev. 2.4

Advertisement

Table of Contents
loading

Summary of Contents for ABB 6310408P

  • Page 1 PRODUCT MANUAL Maintenance Bypass Panel For 827E Inverter Plant 6310408P 6310408P-1 Page 1 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 2: Table Of Contents

    3.5. INPUT ALARM CONNECTIONS FROM THE 827E INVERTER PLANT ·················································· 14 3.6. OUTPUT ALARM CONNECTIONS FROM THE BAYPASS PANEL ·························································· 15 3.7. BAT INPUT ···················································································································································· 16 3.8. VERIFY INSTALLATION IS COMPLETE ····································································································· 16 Page 2 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 3: Foreward

    Please take a moment when the product is new to fill in this information. This data will allow faster service when calling ABB Power to order accessories, spare parts, or request field service. First, locate the product information label. This is typically located on the upper front of the equipment frame, or on the rear of the frame.
  • Page 4: Warnings

    électrique qui peut causer la blessure ou la mort Sérieuse 4. Use of an attachment other than one approved by ABB POWER will void any and all warranties, implied or other, and will increase risk of fire, or may possibly cause electrical shock, injury, or death to personnel L'usage d'un attachement autrement qu'un approuvé...
  • Page 5: Cautions

    (les chargements). Prendre les précautions nécessaires et informer l'ingénieur de plante que le pouvoir de production de système aux chargements seront rendus infirme. Page 5 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 6 Fondez les supports, fusibles, et des disjoncteurs ne doivent pas être chargés à plus de 80 pour cent de leur estimation d'ampère. 6. This equipment is intended for restricted access locations only. Cet équipement est projeté pour les emplacements d'accès limités seulement Page 6 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 7: Theory Of Operation

    1: Theory of Operation The maintenance bypass panel (MBS) is designed to be used with the ABB POWER 827E inverter plant. The main purpose of the MBS is to allow an AC load to be switched from its primary source (Inverters) to an alternate source (commercial AC) and back to the primary source (Inverters) again.
  • Page 8 Page 8 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 9: Installer Informationl

    This section contains information that is intended to help the user install the maintenance bypass panel. Included are physical and electrical specifications. FIGURE 2-1: Front View of the 6310408P 10KVA Bypass Panel FIGURE 2-2: Front View of the 6310408P-1 30KVA Bypass Panel 2.2 Maintenance Bypass Panel Description...
  • Page 10: 827E Inverter System E/W Mbs Wiring Diagram

    Maintenance Bypass Output Out put 1: 120 VAC, 60 Hz, 240Amp max. AC, 1 Phase 2.5 827e Inverter System E/W MBS Wiring Diagram FIGURE 2-3: MBS Wiring Diagram Page 10 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 11: System Installation

    NOTE: ABB POWER recommends that the Maintenance Bypass Panel is installed above the top-most 827E Inverter Shelf (refer to Figure 3-1). ABB POWER recommends leaving one rack mounting space between the MBS and the first Inverter shelf as well as from Inverter shelf to inverter shelf to allow air flow between units for proper heat dissipation (refer to Figure 3-1).
  • Page 12: Utility (Commercial Ac) Input Connections

    3.2 Utility (Commercial AC) Input Connections WARNING: All power should remain in the OFF position for the entire installation section. Serious injury or death could occur from live AC circuits. ABB POWER recommends that Licensed Electricians wire all AC connections into the MBS.
  • Page 13: Inverter Input Connections

    A. With the rear cover still removed, connect the LOAD (output power) from the maintenance bypass panel to the load connections. Refer to Figure 3-5. Each LOAD output connection is made via a compression screw. Maximum size cable is 350 MCM. Page 13 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 14: Input Alarm Connections From The 827E Inverter Plant

    Inverter Shelf Number Inverter Shelf 1 Inverter Shelf 2 Inverter Shelf 3 Inverter Shelf 4 827E Inverter Shelf. Figure 3-6: Alarm Input Connections (from 827E Inverter Shelves) Page 14 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 15 A Capacity Alarm from any of the inverter shelves (1, 2, 3, or 4). CLOSE ON ALARM BYPASS OPEN ON ALARM COMMON CLOSE ON ALARM Compression Figure 3-7: Alarm Output Connections (To customer alarms) Page 15 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 16: Bat Input

    Pin 2 -BATTERY 3.8 Verify Installation Is Complete utility position and verify that the commercial AC power takes over the loads. Move the switch back to the Page 16 © Copyright 2023 ABB. All rights reserved. 827E MBS_MAN Rev. 2.4...
  • Page 17 – in whole or in parts – is prevail. ABB does not accept any responsibility whatsoever forbidden without prior written consent of ABB. for potential errors or possible lack of information in this document.