How to Service for Serial Range (Filter in door)
Step1) Check the part (Filter, Filter Head)
1. Remove the basket
3. Check the Filter (Use flashlight)
1) Check for foreign substance in O-ring area.
2) Check O-ring status(kink, damage)
Step2) Action
1. If foreign substance is found or there is no other problem → remove foreign substance and replace the filter
How to reinstall the filter : See page 5 for filter replacement instructions.
2. If the problems are found in the filter and filter head → change the new filter
How to change the new filter : See page 5 for filter replacement instructions.
Appendix
2. Pull out and then turn it counterclockwise to remove.
Make sure to rotate the filter completely before pulling it out of the head assembly.
4. Check the Filter Head (Use flashlight)
1) Check for foreign substance inside the filter head
2) Check the condition inside the filter head(scratch, damage)