3. How to fix Electric Home Shower.
① The distance of the Unit should be more than 250 mm
from right and left of the wall.
Wall
250 mm
minimum
④ Lead the Flexible Cord to the set thru portion as shown below for electric wiring process.
⑤ • Mount the Unit on the wall with 4 screws.
• Drive each Screw into the two upper Wall Plugs through
the screw holes on the Back Plate.
• After tighten up the two upper
Screws, tighten up the
remaining two Screws.
4. Electric wiring
WARNING
WARNING
① Lead the Flexible Cord connected to ELB terminal inside the unit:
2.5 mm², 3 core Flexible Cord.
② Unscrew the Cord Holder and fix the Flexible Cord. Strip the lead
wire (coating). Fasten the life wire (L) and neutral wire (N) to the
ELB (L,N) and earth wire to the Ground Point with 1 N•m (10 kgf.cm)
torque. Fix back the Cord Holder to its position to clamp the
Flexible Cord.
Cord Holder
5 mm
L
N
1 N•m
98.5 mm
Wall
Screw
Screw
250 mm
minimum
80 mm
View from outside
CAUTION
Wall
Wall Plug
Proper size of Flexible Cord and electric wiring must be installed to avoid
smoke emission and fire hazards.
The home shower must be permanently connected to the electric supply
through the ON/OFF DP (double pole) Switch having a contact separation
of at least 3 mm in all poles incorporated in the fixed wiring. This switch
must be clearly identifiable but out of reach of a person using a fixed bath
or shower.
Ground
L
N
Point
L
N
75 mm
L
N
Flexible Cord
57 mm
13 mm
② Make 4 holes at the wall by means of a drill.
③ Drive a Wall Plug into the hole.
25 mm
Ø6 mm
View from inside
Flexible Cord must enter the Unit thru
designated point only (do not make
additional holes).
⑥ Please ensure the set fixed tightly on the wall by shaking
it left and right.
Back Plate
Note: The Back Plate must be
Screw
mounted with 4 Screws.
ON/OFF DP
(double pole) Switch
Miniature Circuit
Breaker (MCB)
③ Connect wires in correct polarity (L,N).
• Connecting the wires in wrong polarity (L,N) causes an abnormal
condition which may lead to electric leaking, burning and such.
• Before wiring, please check polarity (L,N) with voltage range
of a tester or voltmeter by connecting one terminal of the meter
to earth while the other to one of the
Power-Supply Terminals.
• When the needle of the meter
deflects greatly, the polarity of
the Power-Supply Terminals is 'L'.
- 9 -
Wall Plug
Back Plate
Wall
Wall Plug
Earth
Flexible Cord 2.5 mm², 3 core
L
N
Bath Room
Main Power Board
Earth
Power-Supply
Terminals
Tester