Troubleshooting

Defect
GB
The appliance is not
working.
The fat is not
running into the
fat drip tray 3.
The indicator
lamp 6 is illuminat-
ing and going out
again frequently.
The indicator
lamp 6 does not
illuminate.
If the malfunction cannot be corrected with the above suggestions, or if you have determined that the
malfunction may have other causes, please contact our Customer Service.
28
Cause
The mains plug is not connected to the
mains power.
The mains power socket is defective.
The appliance is defective.
The thermostat 5 has not been correctly
inserted into the socket 1.
The appliance is not standing level.
The appliance is maintaining the set tem-
perature level. To do this, it has to heat up
briefl y every so often.
The appliance has now reached the set
temperature.
The thermostat 5 is not inserted into a
mains power socket.
The appliance is defective.
Solution
Insert the plug into a mains
power socket.
Use a diff erent mains power
socket.
In this case, contact Customer
Services.
Push the thermostat 5 into the
socket 1.
Place the appliance on a level
surface.
This is not a defect.
This is not a defect.
Connect the thermostat 5 to a
mains power socket.
In this case, contact Customer
Services.