7. Daily Maintenance
If the dispenser will not be used for over one week, please empty the water in it and disconnect the
dispenser from power supply. Seal the �lter cartridge and store it in the refrigerator (2-5°C, do not
put it into the freezer). When you use it again, please follow the cleaning procedures for �rst time
use.
Cleaning the raw water tank and the �ltered water jug
• If there are obvious impurities at the bottom of the raw water tank or
�ltered water jug, please rinse it with water and clean it with a cleaning
brush. Clean the raw water tank and the �ltered water jug with a brush at
least once per week.
Descaling of raw water tank
• It is recommended to descale the raw water tank every 3 months to avoid
serious scaling in the raw water tank.
• Descaling procedure: �ll the raw water tank to half-way and add 30g of
citric acid. Stir lightly then soak for 2 hours (do not place the raw water tank
back to the dispenser). Then discard the citric acid solution and clean the
entire water tank with tap water.
* Please buy the cleaning brush and citric acid yourself
8. Filter replacement
Please change the �lter cartridge according to the �lter lifetime indicator on the display panel,
or the suggested replacement cycle. New �lter cartridge can be purchased from authorized
retailers and service centers. The model is ADD583.
Name
Model
Suggested Replacement Cycle
* Only the original Philips �lter cartridge can be used for replacement.
All-in-one RO Filter
ADD583
1 year