Mitsubishi Electric FR-D720-0.4K Instruction Manual page 100

Hide thumbs Also See for FR-D720-0.4K:
Table of Contents

Advertisement

Setting of acceleration/deceleration time and acceleration/ deceleration pattern
(2)
Deceleration time setting (Pr. 8, Pr. 20)
Use Pr. 8 Deceleration time to set the deceleration time required to reach 0Hz from Pr. 20 Acceleration/deceleration reference
frequency.
Set the deceleration time according to the following formula.
Deceleration
=
time setting
Maximum operating frequency - Pr. 10
Example) How to find the setting value for Pr.8 when decreasing the output
frequency from the maximum frequency of 50Hz in 10s with Pr.20 =
120Hz and Pr.10 = 3Hz.
(3)
Set two kinds of acceleration/deceleration times (RT signal, Pr. 44, Pr. 45 )
Pr. 44 and Pr. 45 are valid when the RT signal is ON.
When "9999" is set to Pr. 45, the deceleration time becomes equal to the acceleration time (Pr. 44).
For the RT signal, set "3" in any of Pr. 178 to Pr. 182 (input terminal function selection) to assign the function.
NOTE
When the acceleration/deceleration pattern is S-pattern acceleration/deceleration A (refer to page 100), the acceleration/
deceleration time is the time required to reach Pr. 3 Base frequency.
Acceleration/deceleration time formula when the set frequency is the base frequency or higher
4
×
t=
9
Guideline for acceleration/deceleration time at the Pr. 3 Base frequency of 60Hz (0Hz to set frequency)
Changing terminal assignment may affect the other functions. Set parameters after confirming the function of each
terminal.
REMARKS
The RT signal acts as the second function selection signal and makes the other second functions valid. (Refer to page 117)
If the Pr. 20 setting is changed, the Pr. 125 and Pr. 126 (frequency setting signal gain frequency) settings do not change.
Set Pr. 125 and Pr. 126 to adjust the gains.
When the Pr. 7, Pr. 8, Pr. 44 and Pr. 45 settings are 0.03s or less, the acceleration/deceleration time is 0.04s. At that time, set Pr.
20 to "120Hz" or less.
Any value can be set to the acceleration/deceleration time, but the actual motor acceleration/deceleration time cannot be made
shorter than the shortest acceleration/deceleration time determined by the mechanical system J (moment of inertia) and motor torque.
Parameters referred to
Pr. 3 Base frequency
Pr. 10 DC injection brake operation frequency
Pr. 29 Acceleration/deceleration pattern selection
Pr. 125, Pr. 126 (frequency setting gain frequency)
Pr. 178 to Pr. 182 (input terminal function selection)
98
Pr. 20
T
5
2
× f
T
+
2
9
(Pr. 3)
Frequency setting (Hz)
Acceleration/
deceleration time (s)
5
15
Refer to page 86
Refer to page 110
×
Deceleration time from maximum operating frequency to stop
T: Acceleration/deceleration time setting (s)
f: Set frequency (Hz)
60
5
15
Refer to page 100
Refer to page 154
Refer to page 114
120Hz
× 10s
Pr. 8 =
50Hz - 3Hz
120
200
400
12
27
102
35
82
305
25.5s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents