Mitsubishi Electric FR-D720-0.4K Instruction Manual page 133

Hide thumbs Also See for FR-D720-0.4K:
Table of Contents

Advertisement

Types of Monitor
Unit
PTC thermistor
0.01kΩ
resistance
∗1
Frequency setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter unit (FR-PU04/FR-PU07).
∗2
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
When the operation panel is used, the time is displayed up to 65.53 (65530h) in the indication of 1h = 0.001, and thereafter, it is added up from 0.
∗3
Actual operation time is not accumulated when the cumulative operation time is less than 1h until turning OFF of the power supply.
∗4
When using the parameter unit (FR-PU04/FR-PU07), "kW" is displayed.
∗5
Since the panel display of the operation panel is 4 digits in length, the monitor value of more than "9999" is displayed as "----".
∗6
Larger thermal value between the motor thermal and transistor thermal is displayed.
A value other than 0% is displayed if the surrounding air temperature (heatsink temperature) is high even when the inverter is at a stop.
∗7
The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained values.
REMARKS
By setting "0" in Pr. 52, the monitoring of output speed to fault display can be selected in sequence by
When the operation panel is used, the displayed units are Hz and A only, and the others are not displayed.
The monitor set in Pr. 52 is displayed in the third monitor position. However, change the output current monitor for the motor
load factor.
Initial Value
∗The monitor displayed at power-ON is the first monitor. Display the monitor you want to display on the first monitor and hold
down
for 1s. (To return to the output frequency monitor, hold down
monitor.)
Power-on monitor (first monitor)
Output frequency monitor
Example)When Pr. 52 is set to "20" (cumulative energization time), the monitor is displayed on the operation panel as described
below.
Power-on monitor (first monitor)
Output frequency monitor
(2)
Display set frequency during stop (Pr. 52)
When "100" is set in Pr. 52, the set frequency and
output frequency are displayed during stop and
operation respectively. (LED of Hz flickers during
stop and is lit during operation.)
REMARKS
During an error, the output frequency at error occurrence appears.
During MRS signal is ON, the values displayed are the same as during a stop.
During offline auto tuning, the tuning status monitor has priority.
Monitor display and monitor output signal
Pr. 52 Setting
Operation
PU
Pr. 54 (FM)
panel
main
Setting
LED
monitor
×
64
Second monitor
Output current monitor
Second monitor
Output current monitor
frequency
Output current
Output voltage
Fault display
∗ The set frequency displayed indicates the frequency to be output when the start
Terminal FM
Full Scale Value
Displays the PTC thermistor resistance at
terminal 2 when PTC thermistor protection
is active.
(0.10kΩ to 31.5kΩ) (Refer to page 101)
for 1s after displaying the output frequency
Third monitor
Output voltage monitor
Third monitor
Cumulative energization time monitor
0
During
running/stop
Output
Output
frequency
command is ON. Different from the frequency setting displayed when Pr. 52 = "5",
the value based on maximum/minimum frequency and frequency jump is
displayed.
Description
.
Fault monitor
With fault
Fault monitor
With fault
Pr. 52
100
During
During stop
running
Set
Output
frequency∗
frequency
Output current
Output voltage
Fault display
131
4