List Of Positioning Control Parameters - Toshiba TOSVERT VF-AS3 Manual

Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

3. List of positioning control parameters

■ List of parameters
Title
Common to positioning control
A510
Position control select
Position control Dec. time
A511
for quick stop
Position reference UL upper
A512
4-digits (+side)
Position reference UL lower
A513
4-digits (+side)
Position reference UL upper
A514
4-digits (-side)
Position reference UL lower
A515
4-digits (-side)
Position deviation UL upper
A516
4-digits
Position deviation UL lower
A517
4-digits
Present position UL upper
A518
4-digits (+side)
Present position UL lower
A519
4-digits (+side)
Present position UL upper
A520
4-digits (-side)
Present position UL lower
A521
4-digits (-side)
Position detection limit trip
A522
select
Feedback pulse gain
A524
numerator
Feedback pulse gain
A525
denominator
A526
Feed forward gain
Function
0: disabled
1: point to point
2: pulse train input (single phase)
3: pulse train input (2 phases)
0.0 – 6000.0 (0.00 – 600.00) (s)
0 – 9999
0 – 9999
0 – 9999
0 – 9999
0 – 9999
0 – 9999
0 – 9999
0 – 9999
0 – 9999
0 – 9999
0: Disabled
1: Enabled (E-47 trip)
1 – 9999
1 – 9999
0 – 100
15
Adjustment range
E6582187
Default setting
value
0
Depends on the
capacity
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
0
1000
1000
0

Advertisement