■ List of input/output terminals, monitors, and trips
Number
Input terminal
178/179
Position control ready
180/181
0 point set
Position F/R command for PTI
182/183
input
Position command clear for PTI
184/185
input
186/187
0 point dog start
188/189
Phase initialization
10/11
Preset speed switching 1
12/13
Preset speed switching 2
14/15
Preset speed switching 3
116/117
PID1/2 switching
Output terminal
118/119
Stop positioning completion
214/215
Exceed position limit
During position control(PID1,2
146/147
PID control)
Monitor
Position reference (upper 4
56
digits)
Position reference (lower 4
57
digits)
58
Actual position (upper 4 digits)
59
Actual position (lower 4 digits)
Trip
Preparation signal cut during
E-46
position control
Position detection upper limit
E-47
excess
Function
Monitoring by user-specified unit is made possible by setting the
electronic gears (A524, A525).
Monitoring by pulse of the encoder.
- The preparation signal was turned OFF during position control.
- When A527=2 or 12, the 0 point dog signal was turned OFF
before completion of return to origin operation.
- When A522=1, The current position exceeded the upper limit.
- The ratio of the electronic gear (A524/A525) exceeds the
limitation.
19
Remarks
E6582187