■ List of parameters
Title
Phase setting, orientation
A670
Position initialization select
A671
Initial position
A672
Orientation phase
A673
Orientation tolerance
A674
Orientation frequency
Mechanical gear rate numerator
A675
(For orientation)
Mechanical gear rate
A676
denominator (For orientation)
Accuracy improvement, others
F362
PID1 proportional gain
F363
PID1 integral gain
F366
PID1 differential gain
A314
PID2 proportional gain
A315
PID2 integral gain
A318
PID2 differential gain
■ List of input/output terminals
Number
Input terminal
178/179
Position control ready
190/191
Orientation start
116/117
PID1/2 switching
Output terminal
118/119
Stop positioning completion
Positioning control in operation
146/147
(PID1,2 PID control)
Function
0: Initialize with the input terminal function 188/189
1: Initialize with the Z phase of the encoder
0.0 – 359.9 (°)
0.0 – 359.9 (°)
0.1 – 20.0 (°)
0.1 - 10.00 (Hz)
1 – 9999
1 – 9999
0.01 – 100.0
0.00 – 100.0
0.00 – 2.55
0.01 – 100.0
0.00 – 100.0
0.00 – 2.55
Function
25
Adjustment range
ON
Remarks
E6582187
Default
setting
value
0
0.0
0.0
1.0
1.0
1000
1000
0.30
0.20
0.00
0.30
0.20
0.00