Initialation problem
Initial problems
The text
"Program
load" appear
on the disply
"Error: Testing
Contrast"
appear on the
display.
"Faild to
calibrate opening
mechanism"
appear on the
display.
Triacon AB Sweden
The firmware has been
Yes
erased or a firmware
update has faild. Reload
the firmware.
No or bad signal from the light sensor.
Yes
- Check cable between the sensor and the CPU board.
- Verify function of the light sensor, ref. chapter 5.4.
- Replace CPU board.
Can the
Yes
motor be
turned
manually?
Yes
Move the carriage about 5 cm from left end
position by manually rotate the motor screw.
Switch on the main power and notis any
movements of the carriage.
The motor
runs but only
in one
direction.
No power to the moter.
- Check cable between motor and CPU board.
- Verify function of the motor, ref. chapter 5.5.
- Replace CPU board.
Release the motor and try again. If the motor
No
can not be released, the mechanics has to be
investigated because something is blocking the
motor.
Encoder problems.
Yes
- Check cable between left sensor and CPU board.
- Verify function of left sensor board, ref. chapter 5.3
- Replace the CPU board.