Accessing the pass-thru module CLI locally

Using a null-modem mini-USB to DB-9 RS232 serial cable (not included), connect the pass-thru
1.
module management port to a local client device (such as a laptop computer).
Open a terminal emulation session and set the following parameters:
2.
Parameter
Baud rate
Data bits
Parity
Stop bits
Flow control

Production mode CLI

The CLI provides backward and forward cursor control, backward deletion capability, and a 16-line
history buffer. There is no tab "auto-completion" feature, but if there is enough information to determine
the command to be used, the interface will accept part of the CLI command. For example, entering sys is
enough to enter the system menu.

CLI menu

Command
Main menu
system
port
System menu
info
config
dumpconfig
reset
Port menu
auto
info
Global command
save
Notes:
The port/auto command uses the following format: "/port/auto <uplink|downlink> <port #>
<on/off>". The port number can be a sequence of numbers (e.g., "1 3 5 15") or, if all ports are to
be configured, the "*" option can be used (for example, "/port/auto uplink * off" disables auto-
negotiation on all uplink ports).
The port/info command displays link configuration and status.
Value
9600
8
None
1
None
Result
Displays System menu.
Displays Port menu.
Displays system information.
Enables you to set active or factory default configuration.
Dumps active configuration.
Resets pass-thru module.
Displays Port menu auto-negotiation configuration
details.
Displays port information.
Saves configuration.