Table 3.3 Performance specifications
Item
Conforming standard
CC-Link IE TSN Authorization Class
Transmission speed
Communication method
Number of effective ports
Setup of ports
Applicable
cable
Type of our products
Target transmission distance
Switching method
Series connection
Jumbo Frame
Address table
Power Supply LED
Link/Activity LED
Speed LED
*1 It changes with cables to be used. Please refer to the specification of each cable for details.
*2 It is a case of CC-Link IE TSN/CC-Link IE Field. The latency of the layer 2 switch varies according
to the system configuration and presence of faulty stations as well as each layer 2 switch type.
Before using the Layer 2switch in an actual system, we recommend testing the system in an
environment close to that of the actual system.
*3 To use Jumbo Frame, it is necessary for other network devices of the communication target to be
Jumbo Frame compatible.

◆ Component Names

Power
Supply
LED
Ethernet
port
×5
Link/
Activity
LED
Speed
LED
(Front face)
cable
standards
connector
(Top face)
(Side face)
Figure 4.1 Names of parts
Specification
IEEE 802.3ab 1000BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3 10BASE-T
10/100/1Gbps (auto-recognition)
All ports: Full/Half duplex
AutoMDI/MDI-X
Category 5 or higher UTP / STP cable
IEEE802.3,ANSI/TIA/EIA-568-B
RJ-45 connector
SC-E5EW Series
100 m (max.) *1
Store and forward
20 (max.) *2
Corresponds *3
8k entries
ON : Power is applied. / OFF : Power is off.
ON : Link established, no Activity on cable.
BLINKING : Link established, Activity on cable
OFF : No link activity on cable.
ON : Link is 1Gbps. / OFF : Link is 10/100Mbps.
FG
Power supply terminal block
FG
Serial number
plate
DIN rail
Attachment
- 4 -
Class A
5 ports
Enlarged view
PW1- PW1+ PW2-
PW2+

Advertisement

Table of Contents
loading

Table of Contents