LG GD1329CGU Service Manual page 40

Hide thumbs Also See for GD1329CGU:
Table of Contents

Advertisement

ARNING:
!
Connect the power co r d to the terminal block. Each colo r ed wi r e should be connected to
same color sc r e w . Wi r e color indicated on manual is connected to the same color sc r ew
in block. Failu r e to follow these instructions may r esult in a short or overload.
G r ounding th r ough the neutral conductor is p r ohibited for: (1) new branch-ci r cuit
installations, (2) mobile homes, (3) r ec r eational vehicles, and (4) a r eas whe r e local
codes p r ohibit g r ounding th r ough the neutral conducto r .
construction after January 1, 1996.
1
Remove 3
inches (8.9 cm) of the outer
2
covering from the wire. Strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three wires into a hook shape.
Hot
(Black)
Ground Screw
Ground Wire
!
Attach the two hot leads of the power cord
to the outer terminal block screws. Attach
the neutral wire to the center terminal block
screw. Connect the external ground (if
required by local codes) to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
1" (2.5 cm)
Neutral
Hot
(White)
(Red)
conductor cable.
removal and reinstallation of the drye r.
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole; then thread the power cable
prepared in Step 1 through the strain relief.
40
Terminal
Block
UL-Listed
Strain Relief
UL-Listed
3-Wi re
Power Cord

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents