Chapter 2 Useful Features
2.4.3 Configure HotSpare
There are two kinds of Hot Spare Management Modes as the followings.
•
Dedicated Spare
Once a failed drive is replaced, copyback will be executed. Therefore, the slot of the spare drive is no change.
•
Auto Replace Spare
An autoreplace spare replaces a failed drive to be incorporated into the target array instead. Once a failed
drive is replaced, it automatically becomes a hot spare, copyback will not be executed. Therefore, the slot of
the replaced physical device becomes the slot of the spare drive.
(1)
Assign Dedicated Spare
1.
Connect a physical device for hot sparing, and then turn on the server.
2.
Run HPE Smart Array S100i Utility.
On the TOP menu screen of HPE Smart Array S100i utility, select Array Configuration
The following screen appears.
Express5800/R120h-1M, R120h-2M (2nd-Gen) Maintenance Guide
2. RAID System Configuration