I N PU T TESTIN G
Inputs > Input Testing >
Walk Test All Zones
This menu allows you to test all zones within an area at the same
time. To perform a successfull walk test, each zone in the area
must be sealed and unsealed. Users must have access to the
area they want to test.
Once the mode is activated all zones in the area will be listed
one after the other on the keypad display. As each zone is
successfully tested it will be removed from the list leaving only
those zone still to be tested in the list.
Press [MENU] + [3] + [9] + [0] and select the area to walk test
1)
from the list then press [OK].
2)
The keypad will begin scrolling all of the zones that are to be
tested as per the below display.
To test zone Zn001
open then close
Zone 1 Name
Press OK or MENU
To test zone Zn002
open then close
Zone 2 Name
Press OK or MENU
3)
Open and close each zone in the list. Zones that have been
successfully tested are removed from the keypad scroll list.
When all zones have been tested, the keypad will display:
All zones have been
sucessfully tested
Press OK or MENU
4)
Press [OK] or [MENU] to exit.
Inputs > Input Testing >

Walk Test A Zone

This menu allows you to select a single zone to be walk tested.
To perform a successfull walk test, the sellected zone must be
sealled and unsealled. Users must have access to the zone they
want to test.
1)
Press [MENU] + [3] + [9] + [1] and use the up and down arrows
to highlight the zone you want to walk test in the list and
press[OK]. Alternatively, you can enter the zone number
directly and press [OK].
2)
The keypad will display the zone to be tested.
7-12
Input Programming
-
-
MENU 3-9-0
-
-
MENU 3-9-1
To test zone Zn001
open then close
Zone 1 Name
Press OK or MENU
3)
Open and close the zone that needs to be tested. When the test
has been completed the keypad will display:
Zn001 Zone 1 Name
Test Successful
Press OK or MENU
4)
Press [OK] or [MENU] to exit.
Inputs > Input Testing >

Sensor Watch Time

(*** System Wide Parameter ***)
This menu programs the Sensor Watch Time interval. Zones
programmed for Sensor Watch are required to seal and unseal
at least once within the Sensor Watch Time period or a trouble
message will be displayed on the keypad and a Zone Trouble
report sent.
Valid entries are 1 -255 Days and 0 = Sensor Watch Disabled
1)
Press [MENU] + [3] + [9] + [2]. The keypad will display the
current sensor watch time (Default = 30 days).
Sensor Watch Time
030 Days
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the new Sensor Watch time in
days then press [OK] to save and exit or press [MENU] to exit
without saving.
i
Sensor Watch monitoring is only active when the area is in the
disarmed state. 24 hour zone types cannot be monitored using
the Sensor Watch feature.
Note
» » E N D
MENU 3-9-2
0
S E C T I O N « «
O F
Bosch Security Systems 05/10 BLCC100I