P R O G R A M M I N G O V E R V I E W
The Solution 16i Control System incorporates a ICON
style user interface and includes a text display to show
all programming data in an easy to read format. Once
programming mode is entered you will see a number
of menu options in the display and these may vary
depending in the user authority level.
All user and master code user options include brief text
prompts to simplify operation and reduce the need to
refer to the manual.
Installer programming options are accessed using location
numbers with text prompts showing the current location
number and the data currently programmed.
E N T E R I N G P R O G R A M M I N G M O D E
To enter installer program mode enter, PIN + [MENU].
The default Installer PIN is 1234.
The default Master Code PIN is 2580.
The Red and Green LED indicators on the keypad will flash
to confirm Installer programming mode is active.
All areas must be disarmed with no active alarms. To
i
disarm all areas enter the Installer PIN and hold the
Note
[OFF] Key for 2 seconds.
E X I T I N G P R O G R A M M I N G M O D E
Press and hold down [MENU] key for 2 seconds.
You can also select End from the menu and press
i
[OK] to exit.
Note
P R O G R A M M I N G S T R U C T U R E
The ICON system utilises a mixture of text menus and
location numbers to simplify programming for both end
users and installers.
All programming options can be accessed by entering the
appropriate location or menu number followed by the
[OK] key, however only a limited number of text menus
are provided. As the installer you have access to both
programming methods.
Most end user functions can be accessed via the text menu
which simplifys operation and reduces training time.
Bosch Security Systems 09/11 BLCC500I

Programming Overview

1) Enter Program Mode. [1234 + MENU]
2) Enter the desired location number to program and
press [OK]. Follow the prompts.
3) Alternatively, press [MENU] and use the arrow and
OK keys to navigate through the text menus.
4) At any time you are free to enter the location you
wish to move to followed by the [OK] key.
5) To exit programming navigate to the end option
and press [OK], alternativly hold the [MENU] key
down for 2 seconds.
Key
OK
MENU
0 to 9
ON
OFF
I N T E R P R E T I N G T H E T E X T D I S P L AY
The ICON keypad text display includes space for up to
6 characters to be displayed at one time. To simplify
programming, some text menus have been abbreviated.
The following table list the upper case, numbers and
some of the special characters which can be displayed on
the keypad. See the Character Set Table at the end of this
document for a complete character listing.
Description
Scrolls Cursor Left
Scrolls Cursor Right
Scrolls Cursor Up
Scrolls Cursor Down
Enter Menu Options or Saves Changes
Go Back One Level, Hold Down to Exit
Programming Mode, Abort Changes
Enter Data Value, Toggle Bit Option
Turn On Functions, Accept Data
Turn Off Functions, Clear to End of Line

Table 14: Keys Used During Programming