Kenwood TS-130S Service Manual page 32

Hf ssb transceiver
Hide thumbs Also See for TS-130S:
Table of Contents

Advertisement

32
ADJUSTMENTS
GENERAL
Adjustment
procedures
for this
transceiver
are
classified
into
formal
adjustments
requiring
a
full
service
bench
and
simplified adjustment
using
a VTVM,
AF
and
RF
VITVM,
AG,
and AF and RF dummy load.
Complete
frequency
counter,
adjustment
also
requires
a
SSG, sweep generator, etc.
TEST EQUIPMENT REQUIRED
1. VTVM or DVM
1) Input resistance:
More than 1MQ
2) Voltage range:
1.5 to 1000V AC/DC
NOTE
: A high-precision voltmeter may be used. However, accu-
rate
readings
can
not
be obtained
for high-impedance
circuits.
2. DC current meter
100mA, 200mA,
2A, 10A,
High-precision
current meter may be used.
1) Current range:
3.
RF VTVM
1) Input impedance:
1MQ and less than 3 pF, min.
2) Voltage range:
10mV to 300V
3) Frequency range: 50MHz or greater
NOTE:
During adjustment special accuracy is not required (such as
input
level or PLL
circuit carrier oscillator output),
a VTVM
or
VOM
may substitute for an RF VTVM
by measuring through the
output of a detector as shown in item 14.
4.
AF VTVM
1) Frequency range: 50Hz to 10kHz
2) Input resistance:
1M or greater
3) Voltage range: 10mV to 30V
5.
AF GENERATOR
(AG)
1) Frequency range: 200Hz to 5kHz
2) Output:
2mV~1V, low distortion
6. AF DUMMY
LOAD
1) Impedance:
82
2) Dissipation: 3W or greater
7.
REF DUMMY
LOAD
1) Impedance:
502, 1502
2) Dissipation:
100W continuous or greater
3) Frequency limits: 1.8 to 30MHz
The
above-mentioned
instruments
may
be
used
for simplified
adjustment. For complete, precise adjustment, the following instru-
ments are also necessary.
8.
OSCILLOSCOPE
Requires high sensitivity, and external synchronization
capability.
9. SWEEP GENERATOR
1) Center frequency:
8.83MHz
2) Frequency deviation:
Maximum +5kHz
3) Output voltage: More than 0.1V
4) Sweep rate: At least 0.5 sec/cm
10. Standard Signal Generator (SSG)
1) Frequency range:
1.8 to 30MHz
2) Output:
—20dB/0.1uV~120dB/1V
NOTE:
Generator must be frequency stable.
11.
FREQUENCY
COUNTER
1) Minimum input voltage:
50mV
2) Frequency range:
Greater than 40MHz
12. NOISE GENERATOR
Must generate ignition noise containing harmonics beyond 30MHz.
13. Spectrum analyzer
1) Frequency range:
100K to 110MHz
2) Bandwidth:
1kHz to 3MHz
NOTE:
R-1000 receiver may be used.
14, Detector
1) For adjustment of TX BPF
INPUTO
rege
"2 OUTPUT
To coil pack
10P
IN60
To oscilloscope
GNDO—
3392
)
1N60
J 100r
_oO no
2) For adjustment of PLL unit BPF
INPUT O—
4
0 OUTPUT
To
PLL
unit
oP
IN6O
To oscilloscope
GNDO-
1N60
Tioor
On
15. Directional coupler
16.
FIX-CH adjusting crystal element
1) 5.750MHz (center: 250kHz)
REFERENCE
Japanese '' SSG"'
American''SG"'
—-6dB...............
ee
ee ee eee 0.25uV
OdB..
2...
ee
es 0.5yV
0 |
TeV
12dB.
1.
Le
ee
ees Qu
24dB
we ee ee ees Bu
30dB....
2...
et
ee
et es 15, 8uV
40dB
...
2... ee
ee ee
ee 50uV
50dB
....
ee ee
ee 158uV
60dB
...
2...
ee
ee
ee 500uV
1A | = Sa
1.58mV
B0dB
..
1... 2.
ee
ee
ee 5mV
9QOdB. 1...
ee ee es 15,8mV
100dB
.. 2...
ee
ee
50mV
120dB
..
2...
. ees
O0.5V

Advertisement