oa:
Measuring point
Adjust
ee
Item
Condition
Instrments
Unit
Terminal
Unit
Parts
Reference
Specification/Remarks
5. RIT
1) Adjust VFO
|Frequency |AF-GEN
J1,6P
| AF-GEN
VR1
Altenate RIT
1) No frequency change
frequency to
{counter
ON and OFF
between RIT ON and OFF
5.75MHz
2) More than +1.5kHz variable
2) RIT control:
RIT range
Centered
6. VCO
VFO
BAND
| Oscillator level 1V + 3dB,—1dB
250
3.5
DCVTVM
{PLL
TP1
PLL
T1
3.5V
at J18, 1P on PLL unit
250
7
Frequency
T2
5.5V
7)
a
250
14
counter
T3
4.0V
BAN
250
18
T5
6.1V
(35V)
250
21
T4
3.75V
38 | 129M asem}
500
28.5
4.75V (check)
7.0 | 15.83m | §-5¥) | 16.33m
vcO
16.08M
Common
10.0 | 18.33M | 19.08M | 19.33M
14.0 | 22.83m|
'4Y) | 23.33m
23.08M
21.0 | 29.83m | '3-75V) | 39.33m
VCO
30.08M
Common
24.5
| 33.33M | 33.58M | 33.83M
18.0 | 26.83M
a oer 273M}
28.0 | 36.83M | 37.08M | 37.33M
Common
. 28.5 | 37.33M | 37.58M | 37.83M
29.0 | 37.83M 38.08M | 38.33M
29.5
| 38.33M | 38.58M | 38.83M
Note(
):control voltage
7. TX BPF
MODE:SSB
Sweep
PLL
J18
RF
L7~30 | Adjust coils
(RX BPF)
STBY:SEND — |generator, | RF
DRV
for waveform
Make adjust-
Oscillo-
as shown.
ments in the
scope,
following
Detector
10.125
14.2
sequence:3.5>
|3.5M
3.75
7M
7.0 7.15 7.3
10.375
44M
7710714
.
18>21724.5
—> 28 MHz.
Disconnect
Ripple less than 2dB
Ripple less than 2dB
Ripple less than 2dB
connector J18
on the PLL unit
L10,11,12
L13,14,15
and connect the
{18M
21M
21,25
24.5M
28M
Sweep generator | = 17.875 | 18.125 4 18.375
24.5 24.95 25.35
RF output to it.
Connect the de-
tector input to
L16,17,18
28.0 29.0 30.0
the DRV ter-
than 1dB
Ripple less than 1dB
Ripple less than 2dB
minal on the
RE unit.
L19,20,21
L22, 23,24
L25, 26, 27
L28, 29, 30
8. PLL BPF
1) BPF-A
STBY:REC
Detector,
|PLL
Q16@)|
PLL
T9
Adjust
Disconnect
Oscillo-
T10
T9~T11
for
connectors
scope,
T11
wavetorm as
J17 and J19
Sweep
shown at right.
on the PLL
generator
unit.
Connect the
canoe or PLL
14.23 14.58 14.93
unit to the
AF-GEN unit
jumper wire
next to the D22
VR4
on the AF-GEN|
Jumper wire.
Ln
unit with a lead.
i, I
Connect the
D22 <-
sweep generator
RF output to
L
JS
|
the J19, 3P
(VFO) on the
PLL unit.Con-
nect the de-
tector input to
Q16 emitter on
the PLL unit.