Clear The Event Log - NEC N8154-27 User Manual

3.5 inch disk cage
Table of Contents

Advertisement

⑤ When the following prompt is displayed, the SDR/PIA setup is completed.
Example)
Device ID
Device Revision
BMC Firmware Revision
IPMI Version
Product ID
Boot Firmware Revision : 00.17
PIA Revision
SDR Revision
CFG Identify
Self Test Results
All programming complete!!
Remove CD-R, reset the server for normal operation.
C:>
With reference to N codes of the server, be sure to confirm SDR Rev as follows.
SDR Revision differs depending on the mounted CPU and optional product.
Target server
N8100-1668F/1669F/1670F/1671F/1672F
Power Supply type
HDD type
SDR Revision
Product ID
*
case sensitivity
If "SDR Revision" is not match above list, please check again the jumper setting and cable
connecting.

Clear the event log

① Remove CD-ROM from the optical disk drive, and turn off/on power to reboot the server.
< F2 > key is pushed in POST, and BIOS SETUP is started.
③ Clear the event log by following procedure.
[Server] → [Event Log Configuration] → [Clear All Event Logs] → [Enter] → [YES]
: 38
: 01
: 01.17
: 2.0
: 055A
: 01.06
: 00.03C
: A2MBHR
: 5500
Redundant power unit
3.5-inch
2.5-inch
00.xxc *
00.xxg
Fixed power unit
3.5-inch
2.5-inch
00.xxd
00.xxh
055D
9

Advertisement

Table of Contents
loading