Panasonic HG-S Series User Manual
Panasonic HG-S Series User Manual

Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

Quick Links

For technical/application support or if you want to check availability
contact Ramco Innovations today - email us at nsales@ramcoi.com
WUME-HGS-4
2017.1
panasonic.net/id/pidsx/global
Ramco National
Contact-Type Digital Displacement Sensor
HG-S Series
User's Manual
www.PanasonicSensors.com
1-800-280-6933

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic HG-S Series

  • Page 1 For technical/application support or if you want to check availability contact Ramco Innovations today - email us at nsales@ramcoi.com Contact-Type Digital Displacement Sensor HG-S Series User's Manual WUME-HGS-4 2017.1 panasonic.net/id/pidsx/global Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 2 (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 3 Thank you for purchasing an contact-type digital displacement sensor HG-S series. Before using this product, read and understand this User's Manual. Use the product correctly and in the optimum manner. Keep this manual in a safe location for reference whenever necessary.
  • Page 4: Table Of Contents

    4-2-1 Display Switching Mode ·························································· 4-5 4-2-2 Presets ··············································································· 4-8 4-2-3 Teaching Mode ····································································· 4-11 4-2-3-1 HIGH Set Value Fine Adjustment Function and LOW Set Value Fine Adjustment Function ··················· 4-18 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 5 5-3-9-1 Pressure Check / Pressure Check Set Value / Alarm Delay Count · 5-60 5-3-9-2 Catch Check ························································· 5-64 5-3-9-3 Number of Connected Controllers Check (Master Unit Only) · 5-66 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 6 7-1-1 Maintenance Cautions ···························································· 7-2 7-1-2 Main Inspection Items ···························································· 7-2 ·························································· 7-2 Replacing the Probe ·············································· 7-3 Replacing the Rubber Bellows ······························································· 7-4 Error Messages ······························································· 7-5 Troubleshooting © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 7: Chapter 1 Introduction

    Chapter 1 INTRODUCTION 1-1 Safety Cautions ········································································ 1-2 1-2 Safety Information ····································································· 1-2 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 8: Safety Cautions

    Risk of short-circuiting and damage to the controller or power supply if in- correctly mounted or connected. The controller HG-SC series is designed to be used with the special sensor head HG-S series. If malfunctioning or damage may occur.
  • Page 9 Never remove the standard rubber bellows except for replacement. Risk of product damage Other matters Never attempt to disassemble, repair, or modify the product. When the product becomes unusable or unneeded, dispose of the product appropriately as industrial waste. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 10 (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 11: Chapter 2 Before Using This Product

    Chapter 2 BEFORE USING THIS PRODUCT 2-1 Contents of Package ································································· 2-2 ································································ 2-5 2-3 Description of Parts ··································································· 2-6 2-3-1 Controller············································································· 2-6 2-3-2 Sensor Head ········································································ 2-8 2-3-3 Sensor Head Connection Cable ··············································· 2-8 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 12: Contents Of Package

    Instructions (23 languages): 1 pc. Instruction Manual (English / Japa- nese, Chinese / Korean): 2 pcs. General Information for Safety, Compliance, and Instructions (23 languages): 1 pc. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 13 MS-DIN-E / End plate Plate: Set of 2 pcs. Instruction manual Joint (Option) TR-J102 / Length 15mm type Joint: 1 pc. TR-J104 / Length 25mm type Joint: 1 pc. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 14 TR-S411-K / Flat-seated type Probe: 1 pc. TR-S601 / Roller type Probe: 1 pc. Rubber bellows (Option) TR-G20×5 / 10mm type Bellows: 1 pc. TR-G40×5 / 32mm type Bellows: 1 pc. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 15 BEFORE USING THIS PRODUCT The HG-S series consists of controllers, sensor head connection cables, and sensor heads. For the controllers, master units (2 types) and slave units (5 types) are available. Up to 15 slave units can be connected per master unit. (When communication unit consolidated: up to 14 slave units) For the sensor heads, 5 types are available.
  • Page 16: Description Of Parts

    For details, refer to the following page. 4 Male connector For connection to a master unit or slave unit. Digital display / operation Keep closed when not using. cover © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 17 When short-pressed in the base screen, the preset function turns ON. 19 Preset key When long-pressed for 2 seconds in the base screen, the preset function turns OFF. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 18: Sensor Head

    1 Sensor head connector Connects to the sensor head cable connector on the sensor head. 2 Controller connector Connects to the sensor head cable connector on the controller. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 19: Chapter 3 Installation And Connections

    Chapter 3 INSTALLATION AND CONNECTIONS 3-1 Mounting the Controller ······························································ 3-2 3-1-1 Mounting on a DIN Rail ·························································· 3-2 3-1-2 Removing from a DIN Rail ······················································· 3-2 3-2 Attaching the Sensor Head ························································· 3-3 3-3 Wiring the Controller Connector on the Sensor Head Connection Cable 3-5 3-3-1 Disassembly Procedure ··························································...
  • Page 20: Mounting The Controller

    While pressing down on the rear of the mounting part, insert the front of the mounting part into the DIN rail. 3-1-2 Removing from a DIN Rail Grasp the product and push forward. Lift the front to remove. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 21: Attaching The Sensor Head

    Housing Housing Mounting nut (accessory) Thread Thread Housing thickness HG-S1010(R), HG-S1110(R) 6.5 to 10mm 10 to 12.5mm HG-S1032 6.5 to 8.5mm 8.5 to 10.5mm © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 22 If the rubber bellows is deformed, rotate the bellows to restore to the normal shape. If the rubber bellows is deformed, a load will occur when the spindle operates and damage may result. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 23: Wiring The Controller Connector On The Sensor Head Connection Cable

    7 to 8mm, and twist the core wires several times. Wire Core wire length 7 to 8mm (white) on the operation unit until the lever locks. Flat-head screwdriver Lever (white) Tip width 2mm or less © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 24 Pull on the wire gently to ensure that it does not come out. Slide the protective cover in the direction of the arrow to return the cover to its original position. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 25: Connecting The Controller And Sensor Head

    Turn the fastening ring on the sensor head connector in the direction shown and tighten Fixing ring Do not turn the connector on the L-shaped connector Risk of damage. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 26: Removing The Sensor Head And Sensor Head Connection Cable

    Risk of damage if you pull the cable with excessive force (15N or more) with the fastening ring tightened. If changing the type of sensor head to be connected, always switch the power OFF then © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 27: Attaching The Controller And Sensor Head Connection Cable

    Lock release lever Pull out If you attempt to disconnect the cable by pulling it without pressing the lock release lever, cable wire breakage and connector damage may occur. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 28: Connecting Controllers

    Mount each slave unit one at a time on the DIN rail. Remove all connector covers except for the cover on the end slave unit. Slave unit Slide 3-10 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 29: Removal Method

    Take care if the screw is tightened with a torque of 0.3N•m or more, this product may get damaged. 3-5-2 Removal Method Loosen the screws on the end plates Remove the end plates. Slide and remove the controllers, one at a time. Slide © Panasonic Industrial Devices SUNX Co., Ltd. 2017 3-11 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 30: Connection Diagrams And I/O Circuit Diagrams

    Note: Use shielded wire for the analog output. <Reference> The HG-SC111 and HG-SC111-P cables do not have +V or 0V. Power is supplied from the con- nector of the master unit. 3-12 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 31 (Pink / Violet) External input 3 <Reference> The HG-SC112 and HG-SC112-P cables do not have +V or 0V. Power is supplied from the con- nector of the master unit. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 3-13 Ramco National www.PanasonicSensors.com...
  • Page 32: I/O Circuit Diagrams

    All outputs are equipped with short-circuit protection. If any one of outputs 1 to 3 short-circuits, all outputs temporarily turn OFF. The outputs automatically recover when the short-circuit state is cleared. 3-14 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 33 All outlets are equipped with short-circuit protection. If any one of outputs 1 to 3 short-circuits, all outputs temporarily turn OFF. The outputs automatically recover when the short-circuit state is cleared. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 3-15 Ramco National www.PanasonicSensors.com...
  • Page 34 OFF. The outputs automatically recover when the short-circuit state is cleared. The HG-SC111 cable does not have +V or 0V. Power is supplied from the connector of the mas- ter unit. 3-16 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 35 OFF. The outputs automatically recover when the short-circuit state is cleared. The HG-SC111-P cable does not have +V or 0V. Power is supplied from the connector of the master unit. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 3-17 Ramco National www.PanasonicSensors.com...
  • Page 36 OFF. The outputs automatically recover when the short-circuit state is cleared. The HG-SC112 cable does not have +V or 0V. Power is supplied from the connector of the mas- ter unit. 3-18 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 37 OFF. The outputs automatically recover when the short-circuit state is cleared. The HG-SC112-P cable does not have +V or 0V. Power is supplied from the connector of the master unit. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 3-19 Ramco National www.PanasonicSensors.com...
  • Page 38 (MEMO) 3-20 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 39: Chapter 4 Basic Operation

    Chapter 4 BASIC OPERATION 4-1 Explanation of Basic Operation ···················································· 4-2 4-1-1 From Power ON to Mode Selection ··········································· 4-2 4-1-2 Operation Keys and Display ···················································· 4-3 4-1-2-1 Operation Keys ······················································ 4-3 4-1-2-2 Display ································································ 4-4 4-2 Explanation of Modes ······························································· 4-5 4-2-1 Display Switching Mode ··························································...
  • Page 40: Explanation Of Basic Operation

    (1 to 3). Long- press for 3 seconds Key lock (refer to page 4-24) during measurement. Short press Presets (refer to page 4-8) and shift to any preset value. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 41: Operation Keys And Display

    UP / DOWN key Change setting items [digital display / SUB (green)]. Change set values. ENTER key Finalize setting items and settings. EXIT key Cancel setting items and settings. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 42: Display

    Shows the count when an operation key is long-pressed for 2 seconds. The number of setting items in the level lights up, and the or- der of the setting times is shown by blinking. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 43: Explanation Of Modes

    The judgment value that appears in the digital display / MAIN (white) triggers judgment output ON / OFF based on the LOW set value and the HIGH set value. Analog output is also output based on the judgment value. “5-1-2 Data Flow”. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 44 When the calculation function is not used, this does not appear on either the master unit or the slave units. If you press the ENTER key with "LABEL" selected, you will move to the label setting screen. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 45 BASIC OPERATION Press the UP / DOWN key to change the alphanumeric character. Press the LEFT / RIGHT key to change the digit position. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 46: Presets

    When the preset function turns ON, the preset indicator (green) lights up. If the preset value is set to "0.0000" (default setting), you can perform zero-point adjustment. Preset indicator (green) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 47 MAIN (white) When the upper or lower display limit is exceeded MAIN (white) When an alarm is output SUB (green) When an error is output © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 48 BASIC OPERATION <Canceling a preset> To cancel the preset function, long-press the preset key for 2 seconds. Preset indicator (green) 4-10 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 49: Teaching Mode

    3-point teaching – Highest value HIGH set value Median value LOW set value Lowest value <Reference> To change teaching type, refer to “5-2-4 Teaching Types ( )”. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-11 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 50 The master workpiece is measured. To acquire the master workpiece judgment value, press the ENTER key. When teaching is completed, "GOOD" appears in the digital display / MAIN (white), and the screen. 4-12 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 51 MAIN (white) set is input MAIN (white) When the upper or lower display limit is exceeded MAIN (white) During alarm output SUB (green) When an error is output © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-13 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 52 "SET.1" appears in the digital display / SUB (green), and the digital display / MAIN (white) blinks. "SET.2" appears in the digital display / SUB (green). Measure the second workpiece, and press the ENTER key. 4-14 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 53 The higher judgment value is set as the HIGH set value and the lower judgment value is set as the LOW set value, regardless of the order of steps and 4. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-15 Ramco National www.PanasonicSensors.com...
  • Page 54 Measure the good workpiece, and press the ENTER key. "SET.3" appears in the digital display / SUB (green). Measure the LOW-side defective workpiece, and press the ENTER key. 4-16 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 55 The value between the highest value and the median value is set as the HIGH set value, and the value between the lowest value and the median value is set as the LOW set value. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-17 Ramco National www.PanasonicSensors.com...
  • Page 56: High Set Value Fine Adjustment Function And Low Set Value Fine Adjustment Function

    Press the LEFT / RIGHT key to change the digit position. Press the UP / DOWN key to in- crease or decrease the value. <Reference> If you take no action for 5 seconds, the screen will automatically return to the base screen and the 4-18 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 57 Press the LEFT / RIGHT key to change the digit position. Press the UP / DOWN key to in- crease or decrease the value. <Reference> If you take no action for 5 seconds, the screen will automatically return to the base screen and the © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-19 Ramco National www.PanasonicSensors.com...
  • Page 58: Bank Mode

    As shown below, there are two methods for saving and loading settings to / from a bank. Method Description Save to bank Key operation Load from bank External input Load from bank 4-20 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 59: Saving And Loading By Operation Key

    Press the LEFT / RIGHT key to switch between "SAVE" and "LOAD" . pears in the digital display / MAIN (white). Press the LEFT / RIGHT key to change banks. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-21 Ramco National www.PanasonicSensors.com...
  • Page 60 If you selected "SAVE" in step 3, the current settings are saved to the bank. If you selected "LOAD" in step 3, the settings saved in the bank are loaded. Press the EXIT key twice to return to the base screen. 4-22 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 61: Loading By External Input

    Bank 2 Bank 3 <Reference> For the procedure for setting external input to bank A input or bank B input, refer to 5-3-3 Exter- nal Input ( © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-23 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 62: Key Lock

    When any key is pressed, "LOCK" appears in the digital display / SUB (green), and "ACT" ap- pears in the digital display / MAIN (white). Functions that use external input are enabled. 4-24 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 63 Simultaneously hold down the ENTER key and EXIT key. The digital display / SUB (green) and the digital display / MAIN (white) change as shown below. When "OFF" appears in the digital display / MAIN (white), release the keys. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 4-25 Ramco National www.PanasonicSensors.com...
  • Page 64 (MEMO) 4-26 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 65: Chapter 5 Function Settings

    Chapter 5 FUNCTION SETTINGS 5-1 Overview of Setting Menu ········· 5-2 5-3-7 Scaling Upper Limit Value / Scaling Lower 5-1-1 Menu Structure ····················5-2 Limit Value ( ) ···5-55 5-3-8 Eco Mode ( ) ···················5-58 5-1-2 Data Flow ···························5-4 5-3-9 Alarm Setting ( ) ··········5-59 5-1-3 Setting Items and Default Values ·5-5 5-3-9-1 Pressure Check / Pressure Check Set...
  • Page 66: Overview Of Setting Menu

    [Hold setting] [Input all] [External input] [External output] Number of digits (Master unit only) displayed [HIGH set value] [LOW set value] [Hysteresis] [Teaching type] [Tolerance] [Preset value] © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 67 (Slave units only) Scaling Scaling [Analog scaling] [Eco mode] [Alarm setting] upper limit value lower limit value Preset data [Preset save] Measurement [Lever ratio] [Response time] [Output operation] selection direction © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 68: Data Flow

    *1 When a calculation mode is selected: The number of slave units used in the calculation var- ies depending on the calculation application selection. *2 Only appears during calculation. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 69: Setting Items And Default Values

    3 (3ms) / 5 (5ms) / 10 (10ms) / 100 (100ms) 500 (500ms) / 1000 (1,000ms) <Default value: 100> Output operation (OUTPUT) N.O. (normal open) / N.C. (normal closed) 5-24 <Default value: N.O.> © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 70 (ANA.LO) -199.9999 to 199.9999 (mm) <Default value: 0.0000> Eco mode (ECO) display turn OFF when idle. 5-58 OFF (Eco OFF) / ON (Eco ON) <Default value: OFF> © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 71 Total stroke operation log SUM .REC Maximum peak value MAX. VAL Maintenance 5-91 Maximum peak value opera- formation. MAINTE tion log MAX. REC Over stroke log OVR. NUM © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 72: Basic Settings

    CALC: Only appears on master unit [HIGH set value] [LOW set value] [Hysteresis] [Teaching] [Tolerance<±>] [Preset value] [Preset data selection] [Preset save] [Measurement direction] [Lever ratio] [Response time] [Output operation] © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 73: High Set Value

    CALC: Only appears on master unit : Move through digits : Change value Finalize Setting item Setting range Default value HIGH set value (HI.SET) -199.9999 to 199.9999 (mm) 5.0000 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 74: Low Set Value

    CALC: Only appears on master unit : Move through digits : Change value Finalize Setting item Setting range Default value LOW set value (LO.SET) -199.9999 to 199.9999 (mm) 1.0000 5-10 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 75: Hysteresis

    By setting a hysteresis, the judgment output will remain stable even if the judgment value Fluctuates near HIGH set value or LOW set value HIGH set value Hysteresis Hysteresis LOW set value Stable Judgment value HIGH © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-11 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 76 Long-press for 2 seconds CALC: Only appears on master unit : Move through digits : Change value Finalize Setting item Setting range Default value 0 to 199.9999 (mm) 0.0030 5-12 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 77: Teaching Types

    3-point teaching Highest value HIGH set value Median value LOW set value Lowest value <Reference> For teaching type, refer to 4-2-3 Teaching Mode . © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-13 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 78 CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value 1-point teaching (TCH.1) Teaching type (TEACH) 2-point teaching (TCH.2) TCH.1 3-point teaching (TCH.3) 5-14 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 79: Tolerance

    Long-press for 2 seconds CALC: Only appears on master unit : Move through digits : Change value Finalize Setting Setting range Default value Tolerance (±) (TOL<±>) 0 to 199.9999 0.1000 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-15 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 80: Preset Value

    CALC: Only appears on master unit : Move through digits : Change value Finalize Setting item Setting range Default value Preset value (PR. VAL) -199.9999 to 199.9999 (mm) 0.0000 5-16 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 81: Preset Data Selection

    CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Normal measured value (NORM.V) Preset data selection (PR.OBJ) NORM.V Judgment value (JUDGE.V) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-17 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 82: Preset Save

    CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Preset save OFF (OFF) Preset save (PR.SAVE) Preset save ON (ON) 5-18 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 83: Measurement Direction

    If you change the measurement direction setting, you must also change the settings below. • HIGH set value • LOW set value • Self trigger edge direction in the hold setting © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-19 Ramco National www.PanasonicSensors.com...
  • Page 84 CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Normal display (plus direction ) (NORMAL) Measurement direction (DIRECT) NORMAL Reverse display (minus direction) (REVERS) 5-20 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 85: Lever Ratio

    0.1 to 100.0 (times) <Reference> If the lever ratio is set to a value outside the range, " " will appear in the digital display / MAIN (white). © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-21 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 86: Response Time

    Internal value update cycle: 1ms Response time (10ms) <Reference> To respond to instantaneous changes, set a shorter response time. To disregard instantaneous changes, set a longer response time. count is reached. 5-22 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 87 CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value 3ms (3) 5ms (5) 10ms (10) Response time (SPEED) 100ms (100) 500ms (500) 1,000ms (1000) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-23 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 88: Output Operation

    CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Normal Open (N.O.) Output operation (N.O. / N.C.) N.O. Normal Closed (N.C.) 5-24 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 89: Advanced Settings

    [Input all] [External input] [External output] (Master unit only) [Number of digits displayed] [Analog scaling] [Scaling upper limit value] [Scaling lower limit value] [Eco mode] [Alarm setting] © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-25 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 90: Hold Setting

    Depending on the calculation application selection setting, the hold setting on the slave unit used for calculation may be invalid. 5-26 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 91: Sample Hold

    2. If the reset input turns ON while the external trigger input is ON, the indeterminate state is held. 3. Judgment output outputs the judgment result based on the output setting. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-27 Ramco National www.PanasonicSensors.com...
  • Page 92: Peak To Peak Hold / 2

    NG hold (NG-H) Self sample hold (SLF.S-H) Self peak hold (SLF.P-H) Self bottom hold (SLF.B-H) Setting item Set values Default value Hold (HOLD) Trigger mode (TRG) HOLD One-shot (1SHOT) 5-28 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 93 FUNCTION SETTINGS Setting method Long-press for 2 seconds CALC: Only appears on master unit ALL IN: Only appears on master unit : Select : Finalize © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-29 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 94: Peak Hold, Bottom Hold, Peak To Peak Hold, Peak To Peak Hold / 2 ·5-30 5-3-1-1-3 Ng Hold

    3. If the reset input turns ON while the external trigger input is ON, the indeterminate state is held. 4. Judgment output outputs the judgment result based on the output setting. 5-30 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 95 The judgment value (JUDGE.V) is held in the same way in the respective measurement modes of Bottom hold, Peak to peak hold, and Peak to peak hold / 2. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-31 Ramco National www.PanasonicSensors.com...
  • Page 96 Long-press for 2 seconds CALC: Only appears on master unit ALL IN: Only appears on master unit Status mark - : Select HOLD (white) : Finalize light up 5-32 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 97: Ng Hold

    Once a HIGH judgment is output during one output judgment interval, a LOW judgment is not output. Once a LOW judgment is output, a HIGH judgment is not output. The trigger mode setting is invalid for NG hold. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-33 Ramco National www.PanasonicSensors.com...
  • Page 98 Long-press for 2 seconds CALC: Only appears on master unit ALL IN: Only appears on master unit : Select : Finalize Status mark - HOLD (white) light up 5-34 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 99: Self Sample Hold (Delay Timer)

    5. If the reset input turns ON, the indeterminate state is held. If this occurs during the delay time, the delay time ends. 6. Judgment output outputs the judgment result based on the output setting. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-35 Ramco National www.PanasonicSensors.com...
  • Page 100 Setting item Set values / setting range Default value Delay timer (DLY.TIM) Setting item Set values / setting range Default value 0 to 9999 (ms) 1000 5-36 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 101 : Change value : Finalize : Select : Select : Move through digits Status mark - TRIG (white) and : Change value HOLD (white) light up : Finalize © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-37 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 102: Self Sample Hold (Static Width)

    5. If the reset input turns ON, the indeterminate state is held. If within the sampling interval, the sampling interval ends. 6. Judgment output outputs the judgment result based on the output setting. 5-38 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 103 Setting item Set values / setting range Default value Static width (DLY.WD) Setting item Set values / setting range Default value 0 to 199.9999 (mm) 0.01 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-39 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 104 : Change value : Finalize : Select : Select : Move through digits Status mark - TRIG (white) and : Change value HOLD (white) light up : Finalize 5-40 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 105: Self Peak Hold / Self Bottom Hold

    3. If the reset input turns ON, the indeterminate state is held. If within the sampling interval, the sampling interval ends. 4. Judgment output outputs the judgment result based on the output setting. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-41 Ramco National www.PanasonicSensors.com...
  • Page 106 4. If the reset input turns ON, the indeterminate state is held. If within the sampling interval, the sampling interval ends. 5. Judgment output outputs the judgment result based on the output setting. 5-42 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 107 -199.9999 to 199.9999 (mm) 0.5000 Self trigger edge direction (SLF.EDG) Setting item Set values / setting range Default value Rise (UP) Self trigger edge direction (SLF.EDG) Fall (DOWN) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-43 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 108 Long-press for 2 seconds CALC: Only appears on master unit ALL IN: Only appears on master unit : Move through digits : Change value : Finalize : Select : Finalize 5-44 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 109: Input All ( ) (Master Unit Only)

    Slave Slave Slave Slave Master unit unit unit unit unit <Reference> Input All can only be set on a master unit to which slave units are connected. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-45 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 110 CALC: Only appears on master unit ALL IN: Only appears on master unit : Select : Finalize Setting item Set values Default value Single (ONE) Input all (ALL IN) All (ALL) 5-46 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 111: External Input

    <Reference> For controller I/O circuit diagrams, refer to 3-6-2 I/O Circuit Diagrams . For input all, refer to 5-3-2 Input All ( ) (Master Unit Only) . © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-47 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 112 Bank A / Bank B / Preset (BANK/P) External input (EXT.IN) P/R/T Bank A / Bank B / Reset (BANK/R) Bank A / Bank B / Trigger (BANK/T) 5-48 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 113: External Output

    2 Output state ALL GO Alarm Output state Logic 2 (Connect- (Master ( O n e o f ed control- unit) connected Output state lers) controllers) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-49 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 114 For controller I/O circuit diagrams, refer to 3-6-2 I/O Circuit Diagrams . For the output operation settings, refer to 5-2-12 Output Operation ( For the alarm function, refer to 5-3-9 Alarm Setting ( 5-50 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 115 ALL IN: Only appears on master unit : Select : Finalize Setting item Set values Default value 3-value (3 VAL) 2-value (2 VAL) External output (EXT.OUT) 3 VAL Logic (LOGIC) Logic 2 (LOGIC2) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-51 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 116: Number Of Digits Displayed

    (NORM.V), LOW set value, HIGH set value, sensor head measured values, calculated values, and judgment values (JUDGE.V). Changes to the number of digits displayed setting do not affect judgment output. 5-52 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 117: Analog Scaling

    20mA Judgment value (JUDGE.V) Lower limit value Upper limit value (0mm) (10mm) Current output range 4 to 20mA Resolution Error output Linearity ±0.25% F.S. Maximum load impedance © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-53 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 118 CALC: Only appears on master unit ALL IN: Only appears on master unit : Select : Finalize Setting item Set values Default value Default (DEFALT) Analog scaling (ANALOG) DEFALT Free (FREE) 5-54 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 119: Scaling Upper Limit Value / Scaling Lower Limit Value

    When scaling lower limit value = scaling upper limit value Analog current output Outputs 4mA. 20mA Judgment value (JUDGE.V) Lower limit value = Upper limit value (5mm) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-55 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 120 ALL IN: Only appears on master unit : Move through digits : Change value Finalize Setting item Setting range Default value Scaling upper limit value (ANA.HI) -199.9999 to 199.9999 (mm) 10.0000 5-56 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 121 ALL IN: Only appears on master unit : Move through digits : Change value Finalize Setting item Setting range Default value Scaling lower limit value (ANA.LO) -199.9999 to 199.9999 (mm) 0.0000 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-57 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 122: Eco Mode

    CALC: Only appears on master unit ALL IN: Only appears on master unit : Select : Finalize Setting item Set values Default value Eco OFF (OFF) Eco mode (ECO) Eco ON (ON) 5-58 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 123: Alarm Setting

    When set to ON, an alarm occurs when the pressure set value is exceeded. Pressure check set value Set the pressure check threshold value. Catch check Number of connected control- lers check © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-59 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 124 Alarm not output because recovered Alarm delay count within alarm delay count Outputs HI / GO / LO according to the output setting. Alarm 5-60 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 125: Value / Alarm Delay Count

    CALC: Only appears on master unit ALL IN: Only appears on master unit : Move through digits : Change value Finalize Setting item Setting range Default value 1 to 1000 1000 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-61 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 126: Pressure Check / Pressure Check Set Value / Alarm Delay Count · 5-60 5-3-9-2 Catch Check

    Long-press for 2 seconds CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Check ON (ON) Pressure check (PRS.CHK) Check OFF (OFF) 5-62 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 127 Pressure check set value (PRS.SET) -199.9999 to 199.9999 (mm) 32mm type: 32.0000 If changing the type of sensor head to be connected, always switch the power OFF then ON. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-63 Ramco National www.PanasonicSensors.com...
  • Page 128: Catch Check

    <Reference> This function can only be used when the measurement mode is set to a mode that has external trigger input enabled in 5-3-1 Hold Setting ( 5-64 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 129 Long-press for 2 seconds CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Check OFF (OFF) Catch check (CAT.CHK) Check ON (ON) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-65 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 130: Number Of Connected Controllers Check (Master Unit Only)

    Number of connected controllers Check OFF (OFF) check (CON.CHK) Check ON (ON) <Reference> The number of connected controllers check can only be turned ON at the master unit. 5-66 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 131: Calculation Settings ( ) (Master Unit Only)

    <Reference> If a slave unit is not connected, "Calculation Mode" and "Calculation Application Selection" will not appear. The calculation setting menu only appears on the master unit. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-67 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 132: Calculation Mode

    Setting method Long-press for 2 seconds : Select : Finalize Setting item Set values Default value No calculation (NO.CALC) Calculation mode (MODE) NO.CALC Calculate (CALC) 5-68 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 133: Calculation Application Selection

    "CURVEA" (curvature), or "THICK" (thickness) is selected, the specified number of slave units closest to the master unit will be used for calculation. Slave units other than those units will not be used. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-69 Ramco National www.PanasonicSensors.com...
  • Page 134: Maximum Value

    • The judgment value (JUDGE.V) (calculation result) appears on the digital display / MAIN (white) of the master unit. The normal measured value (NORM.V) appears on the digital display / MAIN (white) of each slave unit. 5-70 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 135: Minimum Value

    • All sensor head indicators show the judgment result of the master unit. • The response time for judgment output is the response time setting on the master unit and slave units plus 3ms. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-71 Ramco National www.PanasonicSensors.com...
  • Page 136: Average Value

    • The hold function cannot be used on the master unit. • The response time for judgment output is the response time setting on the master unit and slave units plus 3ms. 5-72 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 137: Torsion

    • The response time for judgment output from the master unit is the response time setting on the master unit and slave units plus 3ms. <Reference> This application can only be selected when at least three slave units are connected. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-73 Ramco National www.PanasonicSensors.com...
  • Page 138: Curvature

    • The response time for judgment output from the master unit is the response time setting on the master unit and slave units plus 3ms. <Reference> This application can only be selected when at least two slave units are connected. 5-74 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 139: Thickness

    • The response time for judgment output from the master unit is the response time setting on the master unit and slave units plus 3ms. <Reference> This application can only be selected when at least one slave unit is connected. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-75 Ramco National www.PanasonicSensors.com...
  • Page 140: Copy Settings

    Structure of copy settings menu Long-press for 2 seconds CALC: Only appears on master unit On master unit [Copy select indivisual] [Copy select all] [Copy execution] On slave unit [Copy lock] 5-76 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 141 Slave Slave Master unit 4 unit 3 unit 2 unit 1 unit <Reference> Only current settings can be copied. Settings stored in a bank are not copied. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-77 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 142: Copy Select Individual ( ) (Master Unit Only)

    Settings selected for copying are indicated by a checkmark in the basic settings (BASIC) screen and advanced settings (ADVANC) screen. Copied Not copied <Reference> By executing select all, you can copy all settings at once. tings (BASIC) and advanced settings (ADVANC). 5-78 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 143 Long-press for 2 seconds CALC: Only appears on master unit Select item : Select : Change : Change : Select Setting item Set values Default value Copy select individual © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-79 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 144: Copy Select All ( ) (Master Unit Only)

    Long-press for 2 seconds CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Copy select all (CHK.ALL) Do not copy all (NO) 5-80 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 145: Copy Execution ( ) (Master Unit Only)

    Set values Default value Do not execute (NO) <Reference> pears in the digital display / MAIN (white). Copying Done Slave unit Slave unit Master unit : Finalize © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-81 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 146: Copy Lock ( ) (Slave Units Only)

    "LOCK" appears in the digital display / MAIN (white). Copying Done Slave unit (Copy Lock OFF) Slave unit (Copy Lock ON) Master unit : Finalize 5-82 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 147: Bank Settings

    <Reference> Settings loaded from a bank are saved even if the power is turned OFF. For the procedures for saving and loading settings, refer to 4-2-4 Bank Mode . © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-83 Ramco National www.PanasonicSensors.com...
  • Page 148 Set values Default value HIGH set value, LOW set value (THRS) Bank save setting (BNK.DAT) HIGH set value, LOW set value, preset value (THRS.PR) THRS All (ALL) 5-84 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 149: Calibration Settings

    Step 2 Step 3 Measure zero point. Measure target point. Enter span target value. Correct deviation between detected value and target value. Target point Span Zero point © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-85 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 150 Long-press for 2 seconds CALC: Only appears on master unit : Select : Finalize Setting item Set values Default value Default (DEFALT) Calibration selection (CAL.SEL) DEFAUL User settings (USER) 5-86 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 151 UP / DOWN key ( / ) to change values. Setting item Set values Default value Adjustment value 2 User settings (USER) -199.9999 to 199.9999 (mm) 10.0000 (AJ.VAL2) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-87 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 152 When the zero point measured value and target point measured value have been correctly acquired, "GOOD" appears and calibration is executed. Press the EXIT key repeatedly to return to the base screen. 5-88 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 153: Initialization ( )

    For the default value of each setting, refer to 5-1-3 Setting Items and Default Values . <Reference> Executing initialization does not initialize settings stored in a bank. Calibration settings are not initialized. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-89 Ramco National www.PanasonicSensors.com...
  • Page 154 FUNCTION SETTINGS Setting method Long-press for 2 seconds CALC: Only appears on master unit Auto Auto 5-90 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 155: Maintenance

    Maximum peak value operation log value occurred. (MAX.REC) Display units are 1m. Over stroke log (OVR.NUM) Shows a log of the number of times the maximum stroke was exceeded. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 5-91 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 156 Setting item Set values Default value Total stroke operation log (SUM.REC) Maximum peak value (MAX.VAL) Maintenance (MAINTE) Maximum peak value operation log (MAX.REC) Over stroke log (OVR.NUM) 5-92 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 157: Chapter 6 Specifications

    Chapter 6 SPECIFICATIONS ··········································································· 6-2 6-2 Dimensions·············································································· 6-5 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 158 Input 1 / Input 2 / Input 3 can be changed to "Preset / Reset / External input switching Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)" © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 159 7 to 14 units 10mA 5) Do not use or store in an environment that has been pressurized to an air pressure higher than the at- mospheric pressure at 0m. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 160 4) Excludes damage and deterioration to rubber bellows due to external causes. 5) Typical value in a clean environment with no contact with dust or liquids such as water and oil. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 161: Dimensions

    HG-SC112, HG-SC112-P / Slave unit, standard type 15mm or more 21.1 (5.6) 20mm or more 21.5 36.5 (64.8) (58.5) Compatible with 35mm width DIN rail 14.3 R 30mm or more R 30mm or more © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 162 SPECIFICATIONS HG-SC113 / Slave unit, wire-saving type 15mm or more 21.1 (5.6) 21.5 36.5 (64.8) Compatible with 35mm width DIN rail 14.3 R 30mm or more © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 163 4-R2.5 R 30mm or more 10 (2 face ø8 width) -0.022 M8 (P = 0.5) SR1.59 Note: The low measuring force type is not equipped with rubber bellows. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 164 4-R2.5 R 30mm or more (76.8) (3.8) (23) 15mm or more 17.5 17.5 R 30mm or more ø12 -0.027 (P = 0.75) 14 (2 face width) 10.25 SR1.59 © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 165: Chapter 7 Appendix

    Chapter 7 Appendix 7-1 Maintenance and Inspection ························································ 7-2 7-1-1 Maintenance Cautions ···························································· 7-2 7-1-2 Main Inspection Items ···························································· 7-2 7-2 Replacing the Probe ·································································· 7-3 7-3 Replacing the Rubber Bellows ····················································· 7-4 7-4 Error Messages ········································································ 7-6 7-5 Troubleshooting ········································································ 7-7 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 166: Maintenance And Inspection

    • Have any input/output terminals become loose or come OFF? • Is the supplied power within the rated voltage range (24V DC ±10%)? • • © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 167: Replacing The Probe

    Hold the sensor head fastening wrench in place, and turn only the probe. Turn After attaching the probe, wipe the spindle with absolute alcohol to remove any dirt. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 168: Replacing The Rubber Bellows

    Remove the rubber bellows from the spindle. Rubber bellows (option) Fit the new rubber bellows onto the spindle. Insert to the top edge of the spindle as shown below. Insert to top edge © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 169 If the rubber bellows is deformed, restore the normal shape by rotating the bellows or otherwise. If the rubber bellows is deformed, a load will occur when the spindle operates and damage may result. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 170: Error Messages

    Check if an excessive force is applied to the controller or the sensor head. If the product still does not operate normally after you check the above, consult our technical support center. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com...
  • Page 171: Troubleshooting

    The calculation mode is not set correctly. mode. <Important> If the product still does not operate normally after you check the above, consult our technical sup- port center. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 172 (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 173 Revision History 1st edition, November 30, 2015 2nd edition, May 20, 2016 3rd edition, November 15, 2016 4th edition, January 31, 2017 Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 174 (MEMO) Ramco National www.PanasonicSensors.com 1-800-280-6933...
  • Page 175 3. DISCLAIMERS (1) Panasonic Industrial Devices SUNX’s sole obligation and liability under this warranty is limited to the repair or re- placement, or refund of the purchase price, of a defective Product, at Panasonic Industrial Devices SUNX’s option.
  • Page 176 Overseas Sales Division (Head Office): 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global For sales network, please visit our website. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 January, 2017 PRINTED IN JAPAN WUME-HGS-4 Ramco National www.PanasonicSensors.com...

Table of Contents