Hitachi airCore 700 Installation & Maintenance Manual page 41

Table of Contents

Advertisement

10.1.2 Zone Operation Setting
This function is to set operation (ON/OFF) of individual zone.
Step1. Press " " or " " to select "ON/OFF".
Step2. Press " " or " " to set zone operation.
NOTES:
When "Spill zone control on" displays in the bottom left corner, spill zone enters automatic control, and the
actual state of the zone may not be consistent with the set state.
During Setback operation, Zoning Kit does not accept zone settings.
Even if the parameters are modified, they will be restored after one second.
10.1.3 Zone Set Temperature Setting
This function is to adjust "set temperature" of individual zone.
Step1. Press " " or " " to select "Temp".
Step2. By pressing " ", the temperature is increased by 0.5°C or 1°C.
By pressing " ", the temperature is decreased by 0.5°C or 1°C.
NOTE:
The set temperature of the zone can be set to ±3°C of zone base temperature(within the range of upper and
lower limit of the set temperature).
INSTALLATION & MAINTENANCE MANUAL
ON
On5O77
Spill zone control on
Spill zone control on
Zone average room
temperature
37
Living
Zone 1 (Spill Zone)
2P.5
26.P
26
C
.5
Temp
LoR
Back
ON
OFF
OÃÂOÄÄ
OÃÂOFF
Zone base temperature
Living
Zone 1 (Spill Zone)
2P.5
26.P
ON
26
C
.5
On5O77
Temp
LoR
Back
Zone set temperature