Use Of Oil And Uv Dye Bottles; Turning On The Station; Language Selection; Unit Of Measurement Selection - Bosch ACS 663 Manual

Hide thumbs Also See for ACS 663:
Table of Contents

Advertisement

5.4

Use of oil and UV dye bottles

!
Only use UV contrast liquids and oils that are
approved by the vehicle manufacturer. This prevents
chemical incompatibility with the station internal
components. In the event of problems and failures
due to non-approved liquids, the warranty will be
void.
1. Unscrew the "PAG", "POE", "UV Dye" bottle covers
and remove them.
2. Fill the 3 bottles with compressor oil for PAG and
POE or UV dye at maximum to the "MAX FILL" line.
3. Screw the 3 covers.
4
3
Fig. 12:
Position of bottles
1 UV dye bottle
2 New oil bottle (POE)
3 New oil bottle (PAG)
4 Exhausted oil bottle
4. Place the bottles in the appropriate front area of the
station in the order shown in the figure. To secure
them, make sure that each of them is aligned with
the respective bracket/fitting and have a slight
pressure in the straight direction to the station.
5.5

Turning on the station

1. Connect the power cable to the socket on the
station and to a outlet with the correct voltage,
equipped with grounding.
i
Do not use a power cable with inadequate
characteristics.
2. Place the station so that the plug and power switch
are at the operator's reach.
3. Make sure that the ventilation grille, on the left of
the station, is not obstructed.
4. Lock the front wheels.
5. Turn the power switch on/off lever clockwise to turn
on the station.
"
The first time that the station is switched on, the
Initial Setup mode starts automatically. The software
displays the license agreement after the language
selection, this must be accepted by the user with
Robert Bosch GmbH
5.6
Choose the user interface language. The default
language is English.
1. Use the Up or Down arrow button to scroll through
the available languages, one line at a time.
2. Select
5.7
Set the units of measurement to be displayed. The
default ones are metric units.
1. Use the Up or Down arrow button to select between
the metric or British imperial system.
2. Select
displayed effective.
5.8
Use the arrow buttons to move the cursor. Use the
keypad to change the displayed information.
1. Use the Up or Down arrow buttons to change the
1
item displayed: day, month, year, or time.
2. Use the multi-touch interface on the numeric keypad
2
to change the information.
3. Select
5.9
The information loaded in Print header change will
appear on each print.
1. Enter the text using the arrow buttons and the multi-
touch interface on the numeric keypad:
+
+
+
+
2. Select
.
Initial settings | ACS 663 | 53

Language selection

to set the selected language.

Unit of measurement selection

to make the unit of measurement

Setting the date and time

to save.

Print header change

the button
acts as a backspace key.
The Right or Left arrows button moves the cursor
to the right or left.
The Zero (0) key also acts as a space bar.
To navigate within the rows, use the Up and
Down arrow keys.
to save.
SP00D00616
en
|
2019-11-08

Advertisement

Table of Contents
loading

Table of Contents