E6A: Heating Relay Sensing Faulty; E6H: Heating Element Power Relay Faulty (Incongruence Between Sensing And Relay Status) - Electrolux EWM0931 Series Service Manual

Table of Contents

Advertisement

E6A
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms
E6H: Heating element power relay faulty (incongruence between
E6H
Checks to perform:
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
-(see fig. 6)-
Is the circuit open?
Y
E
S
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms
Fig. 15
Fig. 6
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x

E6A: Heating relay sensing faulty

Check that all the connectors are inserted correctly
sensing and relay status)
Check that all the connectors are inserted correctly
Detach the connector
and measure between
the heating element
and the earth contact.
NO
- (see fig 15) -
Is the circuit open?
Check/replace the wiring and repeat the diagnostic cycle to
General
earthing
connection
Heating
element
NO
Y
E
S
check for any further alarms.
54/67
If there are burns on the circuit
board, see page 65
Run phase 8 of the
diagnostic cycle, drain water
from the tub. Replace the
heating element and repeat
the diagnostic cycle to
check for any further alarms.
MAIN PCB
If there are burns on the circuit
board, see page 65
599 72 97-24
E6A
E6H

Advertisement

Table of Contents
loading

Table of Contents