3 DIAGNOSTIC SYSTEM
3.1 Accessing diagnostic
All versions
A5-A6
1. Set the selector knob to position 0 (zero).
2. Press the START/PAUSE button and the nearest option button simultaneously (as shown in the
figure).
3. Holding down both buttons, switch the appliance on by turning the programme selector by one position
clockwise.
4. Hold the buttons down until the LEDs start to flash (at least 2 seconds).
In the first position, the operation of the buttons and the related LEDs is checked; turn the programme
selector knob clockwise to run the diagnostic cycle for the operation of the various components and to
ready any alarms.
3.2
Quitting the diagnostics system
→ To quit the diagnostics system, turn the selector knob to position 0, turn the appliance back on and
return the knob to position 0.
2010 SOI/DT-mdm FCPD-dp Quality tb
Guide to diagnostics for electronic controls EWM0931x
A3
Z5-Z6
7/67
Z3
K6.2
599 72 97-24