E71: Washing Ntc Probe Faulty - Electrolux EWM0931 Series Service Manual

Table of Contents

Advertisement

E71
Checks to perform:
Run phase 6 of the diagnostic cycle
and wait for the water to fill. Switch
the appliance off and measure the
value of the NTC probe between
contacts J7-4 and J7-5 of the wiring
connector
-see fig. 4-.
Is the value correct?
(between 5.7 - 6.3 KΩ at 20°C)
Y
E
S
Measure between terminals J7-4,
J7-5 of the NTC connector and the
appliance body – (see fig. 6) -
Is there any dispersion?
Y
E
S
Detach the connector and measure
directly between the terminals of the
NTC probe and the appliance body
(there must be water in the tub).
Has dispersion been measured?
Y
E
S
Run phase 8 of the diagnostic cycle,
drain water from the tub. Replace the
washing heating element and repeat
the diagnostic cycle to check for any
further alarms.
MAIN PCB
5.7-6.3KΩ
(20°C)
Temperature probe
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x

E71: Washing NTC probe faulty

Voltage value out of range (short-circuit or open circuit)
Check that all the connectors are inserted correctly
NO
NO
NO
Fig. 6
Heating
element
Detach the connector
and measure directly
on the NTC probe.
- (see fig 14) -
Is the value correct?
(5.7 - 6.3 KΩ at 20°C)
Y
E
S
Check/replace the wiring and repeat the diagnostic
cycle to check for any further alarms.
Replace the circuit board and repeat the diagnostic cycle
to check for any further alarms.
Check/replace the wiring and repeat the diagnostic cycle
to check for any further alarms.
J14
J5
J4
GND
Fig. 4
55/67
Run phase 8 of the
diagnostic cycle,
drain water from the
tub. Replace the
NO
washing heating
element and repeat
the diagnostic cycle
to check for any
further alarms.
Fig. 14
J8
J11
J13
J10
J6
If there are burns on the circuit
board, see page 65
599 72 97-24
E71
J7