Specifications; General Specifications - Mitsubishi Electric AJ71C24-S6 User Manual

Melsec-4 computer link module
Table of Contents

Advertisement

3. SPECIFICATIONS
MELSEC-A
3.
SPECIFICATIONS
3.1
General Specifications
Table 3.1 General S~ecifications
Operating ambient
temperature
Storage ambient
temperature
Operating ambient
humidity
Storage ambient
humidity
Vibration resistance
Shock resistance
Noise resistance
Dielectric withstand
voltage
Insulation resistance
Operating ambience
Cooling method
~
--
Specifications
0 to 55•‹C (32 to 131•‹F)
-20 to 75' (4 to 167•‹F)
10 to 90% RH, no condensation
10 to 90% RH,
no
condensation
I
Frequency
Conforms
l o t o 55 Hz
091 1
I
Sweep
Accelera- Amplitude
tion
(0.003 inch)
minute)
L
Conforms to JIS C 0912 (10
g
x 3 times in 3 directions)
By noise simulator 1500 V.P.P. noise voltage. 1
psec
noise width
and 25 to 60 Hz noise frequency
500 VAC for 1 minute across batch of D C external terminals and
ground
50 MQ or more with 500 VDC insulation resistance tester at the
same location as dielectric strength.
No corrosive gases or dust.
Self-cooling
(1) One octave marked
*
indicates a change from the initial frequency to double or half
frequency. For example, any of the changes from 10 Hz to 20 Hz, 20 Hz to 40 Hz, 40 Hz to
20
Hz,
and 20
Hz
to 10 Hz are referred to as one octave.
(2) The noise durability and dielectric withstand voltage values were obtained with the RS-232C
and RS-422 interfaces unconnected.
'*
JIS: Japanese Industrial Standard