Download Print this page
Panasonic LS-H Series Instruction Manual
Panasonic LS-H Series Instruction Manual

Panasonic LS-H Series Instruction Manual

Laser sensor head

Advertisement

Quick Links

INSTRUCTION MANUAL
Laser Sensor Head
MJE-LSH100 No.0099-24V
Thank you very much for purchasing Panasonic products. Read this Instruction Man-
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference.
WARNING
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which
meet standards, such as OSHA, ANSI or IEC etc., for personnel protection ap-
plicable in each region or country.
Avoid observing beams in a dark surrounding environment.
Do not look at beams using an optical device such as an optical telephoto system.
Never attempt to disassemble, repair, or modify this product.
Use of control or adjustment or performance of procedures other than those
1
REGULATIONS AND STANDARDS
This product complies with the following standards and regulations.
<Conformity Directives / Conforming Regulations>
EU Law:EMC Directive 2014/30/EU
British Legislation:EMC Regulations 2016/1091
Applicable Standards
EN IEC 60947-5-2
2
FOR SAFE USE OF A LASER PRODUCT
IEC/EN/JIS/GB/KS
In order to prevent user injury caused by a laser product, the following standards
have been established in the IEC Standards, EN Standards, JIS Standards, GB
Standards, KS Standards and FDA Regulations.
IEC : IEC 60825-1:2014
EN : EN 60825-1:2014/A11:2021
JIS : JIS C 6802:2014
GB : GB 7247.1-2012
KS : KS C IEC 60825-1:2014
FDA : PART 1040.10, 1040.11(Laser Notice No.56 applied)
safety preventive measures to be implemented for each class.
This product is equivalent to a "Class 1 Laser Product" based on IEC 60825-1:2014(EN
60825-1:2014/A11:2021) "Radiation Safety Standards for Class 1 Laser Products".
Laser hazardous class
(EN 60825-1:2014/A11:2021)
Class
Class 1
Safe under reasonably foreseeable conditions of operation
FDA
Export to the USA.
regulations of the laser standards of the FDA (Food and Drug Administration). In
order to prevent user injury caused by a laser product, Part 1040 (Performance
Standards for Light-Emitting Products) of the FDA standards has been estab-
specify safety preventive measures to be implemented for each class.
This product complies with the FDA regulations (FDA 21 CFR 1040.10 and
IEC 60825-1 Ed. 3.(Class 1 Laser Product)
Label
product.
Label position
3
PART DESCRIPTION
Operation indicator (Orange)
Operation indicator (Orange)
Operation indicator (Orange)
Lights up when the output is ON
Lights up when the output is ON
Lights up when the output is ON
4
MOUNTING
12mm
Attached toothed lock washer
M6
The tightening torque should be 0.98N·m or
less.
Mounting plate
Metal plate
MS-EXL2-2 (Accessory)
In case mounting this device, use a metal
13mm
plate MS-EXL2-2 (accessory).
The tightening torque should be 0.5N·m or
less with M3 screw with washer.
t0.8mm
8.2mm
M3 screws with washers
(Purchase separately)
In case using the dedicated sensor mounting bracket MS-EXL2-1 (optional) when
mounting this device, the metal plate MS-EXL2-2 (accessory) is required depend-
ing on the mounting direction. Mount as the diagram below indicates.
<Not requiring the metal plate>
<Requiring the metal plate>
Sensor mounting bracket
Metal plate
Metal plate
MS-EXL2-1 (Optional)
(Accessory of MS-EXL2-1)
MS-EXL2-2 (Accessory)
M3 (length: 14mm)
screws with washers
(Accessory of MS-EXL2-1)
The tightening torque should be 0.2N·m or less.
Metal plate
14mm
(Accessory of MS-LS-1)
Sensor mounting bracket
MS-LS-1 (Optional)
19mm
M2 (length: 12mm)
screws with washers
(Accessory of MS-LS-1)
tection.
<Fig. 1 Proper positioning>
Correct
<Fig. 2 Improper positioning>
Incorrect
5
) may be unable to detect a
In this case, take the following measures.
<Measures>
• Lower the receiving light sensitivity with the light-receiving sensitivity function of
• Change the response time.
• Make the distance between the sensor head and the sensing object farther.
The receiving light sensitivity may change depending on the surface condition of
6
WIRE CONNECTION
The cable of sensor head can be shortened to your desired length. However, it
Wire inlet
Operating lever (white)
Wire inlet
Strip gauge
Releasing slot
Operating lever
(white)
Wire connecting procedure
1. Process the core length to 7mm to 8mm in
accordance with "STRIP GAUGE" indicated
on the side of this unit, and twist the core
several times.
7mm to 8mm
When using shielded wires, twist the wire un-
til obtaining the diameter of ø1.2mm or less.
2. Use a flathead screwdriver (Blade width:
Flathead
screwdriver
2 mm or less) to push the operating lever
(white) located at the operating area until it is
locked.
Blade width
2mm or less
3. Insert the wire to the innermost of the wire
inlet. Check that the shielded wire is properly
Wire connection area
inserted into the wire inlet as well as that the
core end has passed through the wire con-
-
-
Terminal No.
Connecting cable
1
Purple
1
Thru-beam type · Emitter: Gray
2
White
2
3
3
Shield
4
4
Shield
5
Thru-beam type · Receiver: Black
5
Black
6
6
Pink
4.
-
derneath the operating lever (white) through
the releasing slot, and lift the screwdriver
head. If you hear a snap, the operating lever
5. Lightly pull the wire to ensure that wire is not
loose.
Releasing procedure
1. Remove
1. Use a flat-head screwdriver (Blade width:
2mm or less) to push the operating lever
(white) located at the wire inlet and remove
the wire.
7
SPECIFICATIONS
Thru-beam type
Type
-
Cylindrical
Model No. (Note 2)
LS-H101
STD mode
LONG mode
Sensing
U-LG mode
range
0m to 1m
HYPR mode
(Note 3)
H-SP mode
FAST mode
Ambient temperature
-10°C to +55°C (No dew condensation or icing allowed), Storage: -20°C to +70°C
Ambient humidity
LS-500
Red semiconductor laser Class 1 [IEC / EN / JIS / GB /KS Standards / FDA Regulations (Note 4)]
Emitting element
Peak emission wavelength: 660nm
Enclosure: Stainless steel
Material
Front cover:
Polycarbonate
2
0.09mm
2-core shielded cable, 2 m
Cable
6.562 ft long
Weight
M6 nut: 4 pcs.
Accessories
Toothed lock washer
: 2 pcs.
(e.g.) LS-H901-Y
Release lever
-C5" stands for the 5m cable length type.
(e.g.) LS-H101-C5
4) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA
8
CAUTIONS
Wire
Core length
for malfunction or break down. Hence, please ensure to use this product along with
This product has been developed / produced for industrial use only.
2. Push
Operating lever
(white)
In case noise generating equipment (switching regulator, inverter motor etc.) is
used in the vicinity of this product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
Do not use the sensor during the initial transient time (0.5 sec.) just after the
power supply is switched on.
Shielded wire
3. Insert
Do not use the sensor during the initial transient time (0.5 sec.) just after the
Wire
power supply is switched on.
inlet
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
When using the thru-beam type LS-H101 or LS-H102, do not set the receiving
light sensitivity (gctL) of the applicable LS-500
This is because there is a possibility of sensing becoming unstable.
Core end
performance.
Make sure that stress is not applied to the sensor head cable joint.
This sensor is suitable for indoor use only.
etc., which may block light, to stick to the emitting/receiving surfaces of the sensor
head. In case they are present, wipe them with a clean, soft cloth or lens paper.
Do not use the sensor in vaporous, dusty or corrosive gas atmospheres.
Take care that the sensor does not come in contact with water, oil, grease or or-
ganic solvents, such as, thinner, etc.
4. Lift
the sensor head.
When carrying out teaching using the applicable LS-500 series amplifier, set
sensing will become unstable.
Operating lever
(white)
This device is using a laser which has high directional quality. Therefore the beam
Releasing slot
possibly be out of alignment by the mounting condition of this device or distortion
tion and the sensitivity adjustment must have some margins.
Flathead
screwdriver
Operating lever
(white)
Panasonic Industry Co., Ltd.
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
https://industry.panasonic.com/
Please visit our website for inquiries and about our sales network.
Panasonic Industry Co., Ltd. 2024
April, 2024
-
tive type (Note 1)
type
Small
LS-H102
LS-H901
LS-H201
LS-500 series
0.01m to 1m
0mm to 300mm
0.01m to 1.5m
0mm to 450mm
0.01m to 2m
0mm to 600mm
0m to 1m
0.01m to 2.5m
0mm to 750mm
0.01m to 1m
0mm to 150mm
0.01m to 1m
0mm to 200mm
35% to 85% RH, Storage: 35% to 85% RH
less, Peak emission
less, Peak emission
wavelength: 660nm
wavelength: 660nm
Enclosure:
Enclosure: Polybutylene terephthalate
Polybutylene terephthalate
Front cover: Glass
Front cover: Acylic
2
0.09mm
2-core two parallel shielded
cables, 2 m 6.562 ft long
RF-330
MS-EXL2-2
1 pc.
MS-LS-1
(Metal plate): 2 pcs.
MS-LS-1
(Metal plate): 1 pc.
(Metal plate): 1 pc.
-Y" is the sensor without the RF-330
LS-500 series.
-
-
PRINTED IN JAPAN

Advertisement

loading

Summary of Contents for Panasonic LS-H Series

  • Page 1 • Lower the receiving light sensitivity with the light-receiving sensitivity function of Sensing U-LG mode 0.01m to 2m 0mm to 600mm Thank you very much for purchasing Panasonic products. Read this Instruction Man- range 0m to 1m 0m to 1m HYPR mode 0.01m to 2.5m...
  • Page 2 F D A F o o d a n d D r u g Administration PART1040 Performance Standards for Light-Emitting Products • LS-500 Laser Notice No.56 IEC 60825-1 Ed. 3 FDA 21 CFR 1040. 10 1040.11 “ ” • • Panasonic Industry Co., Ltd. 2024...

This manual is also suitable for:

Ls-h101Ls-h102Ls-h901Ls-h201