2.8 Connection of DECT Portable Stations
3.
After setting the DIP switch, connect an AC adaptor or battery box to the CS using a power supply
adaptor.
Notes
The AC adaptor should be connected to a vertically oriented or floor-mounted AC outlet. Do not
connect the AC adaptor to a ceiling-mounted AC outlet, as the weight of the adaptor may cause it
to become disconnected.
For users in the United Kingdom:
240 V AC must not be used on a building site. Instead of an AC adaptor, connect a battery box to
the CS.
Modular
4.
Install the CS temporarily for the site survey. Install the CS at least 2 m above the floor, keeping the
antennas in the upright position.
156
Installation Manual
Telephone Cord
Power Supply Adaptor
(PSZZ1TDA0142)
To AC Adaptor (KX-A11/KX-TCA1)/
Battery Box (PSZZTD142CE)