Error information page

When
Depending on the nature of the error, the projector may be placed in the standby mode for its own
protection.
When [FAILED] has appeared for an item
Parameter
MAIN CPU BUS
FAN
OPTICS MODULE TEMPERATURE
INPUT AIR TEMPERATURE
OUTPUT AIR TEMPERATURE
LAMP REMAIN TIME
LAMP STATUS
APERTURE
(CONTRAST-SHUTTER)
SHUTTER
(MUTE-SHUTTER)
DIRTY AIR FILTER
AIR FILTER CLEANER UNIT
OPTICS MODULE TEMP.SENSOR
INPUT AIR TEMP.SENSOR
OUTPUT TEMP. SENSOR
BATTERY
CLOGGED FILTER SENSOR
AC POWER
LENS SHIFT
is displayed on the status information screen, click it to display the error details.
Trouble has occurred in the microcomputer circuitry. Consult your dealer.
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
The temperature inside the projector is high. It may be that the projector is
being used in an operating environment where the temperature is high such as
near a heating appliance.
The input air temperature is too high. It may be that the projector is being used
in an operating environment where the temperature is high such as near a
heating appliance.
The temperature around the lamp is too high. It may be that the projector's
ventilation holes are blocked.
The lamp runtime has exceeded the prescribed cumulative time, and it is now
time to replace the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
Trouble has occurred in the shutter circuitry. Consult your dealer.
The air filter is blocked with dust.
Turn off the MAIN POWER switch by following the procedure on page 39, and
then clean the air filter. (pp. 112-113)
The air filter unit is not installed. Install the air filter unit.
Trouble has occurred in the temperature detection sensor inside the projector.
Consult your dealer.
Trouble has occurred in the sensor used to detect the input air temperature.
Consult your dealer.
Trouble has occurred in the sensor used to detect the exhaust air temperature.
Consult your dealer.
The backup battery has been run out. Consult your dealer.
Problem with clogged filter sensor. Consult your dealer.
AC power supply voltage input has dropped. Check that there is sufficient
electrical wiring capacity for the projector's power consumption requirements.
Problem with lens shift circuit. Consult your dealer.