Installing a DSX Analog Door Box and 2PGDAD Module

Mounting the 2PGDAD Module and Connecting to the System

To mount and connect the 2PGDAD Module:
1.
Mount two suitable fasteners (such as #8 sheet metal screws) about 3 15/16" apart either horizontally (for
horizontal mounting) or vertically (for vertical mounting).
- Leave the heads exposed about 1/4"
2.
Place the 2PGDAD Module over the screws and slide down into place.
3.
Program the Door Box and 2PGDAD Module before connecting to the 2PGDAD modular jack.
- In 1203-01: Secondary Station Port Assignment, for the 16ESIU port selected enter an available
- In 2113-02: Ring Group, assign the extensions associated with the 2PGDAD Module and all tele-
- Refer to the Door Box feature in the DSX Software Manual for additional programming.
4.
Using a standard line cord, plug the 2PGDAD Module into its modular jack and verify the LEDs.
4
60 ◆ Optional Equipment
station port for the secondary port (96-127 by default).
phones that should receive door chimes to the same Ring Group.
4
Figure 45: Mounting and Connecting the 2PGDAD Module