3

Accessing the converged network switch

Accessing the converged network switch

The converged network switch is managed as a single element. It has a single IP address and
appears as a separate entity to the Telnet protocol and the Simple Network Management Protocol
(SNMP).
When SNMP devices send SNMP messages to a management console running SAN management
software, the information is stored in a Management Information Base (MIB). The switch module
OS supports the FibreAlliance Fibre Channel Management (FCMGMT) MIBs, allowing the provision
of needed information to a SAN administrator.
Secure Telnet access is available using Secure Shell (SSH), a network security protocol for secure
remote login and other secure network services over an insecure network.
Browser-based GUI management is available through a secure browser using Secure Sockets Layer
(SSL). The SSL security protocol provides data encryption, server authentication, message integrity,
and optional client authentication for a TCP/IP connection. Because SSL is built into all major
browsers and Web servers, installing a digital certificate enables the SSL capabilities.

Interpreting POST results

The power-on self test (POST) system check is performed each time the converged network switch
is powered on, rebooted, or reset.
Example POST Output
During POST, the LEDs are activated in various indicator patterns.
Perform the following steps to determine POST completion status.
1. Verify that the LEDs on the converged network switch indicate a healthy converged network
2. Use the Blade Server Enclosure's Chassis Management Controller (CMC) GUIto verify that the
3. Review the system log for errors.
22
POST1: Started running Fri Oct
POST1: Test #1 - Running ceeturboramtest
POST1: Running diagshow
POST1: Script PASSED with exit status of 0 Fri Oct
(0:0:29)
POST2: Started running Fri Oct
POST2: Test #1 - Running ceeportloopbacktest (SERDES)
POST2: Test #1 - Running ceeportloopbacktest (BACKPLANE)
switch. LED patterns are described in
If one or more LEDs do not display a healthy state, verify that the LEDs are not set to beacon.
Use the switch module CLI switchShow command or the browser-based GUI to verify the LED
state.
converged network switch is working correctly.
For details, refer to the Hardware Owner's Manual for the Blade Server Enclosure.
Any errors detected during POST are written to the system log. Access this log through the
Module's CLI errShow command.
8 13:39:25 GMT 2010
8 13:39:54 GMT 2010 took
8 13:39:54 GMT 2010
"Interpreting LED activity,"
Dell M8428-k Hardware Reference Manual
next.
53-1001980-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge m620Poweredge m915

Table of Contents