Table 1-8. System Messages (continued)
Message
Read fault
Requested sector not found
Remote Access Controller
cable error or incorrect
card in the RAC slot.
Remote Access Controller
not installed in the RAC
slot.
Remote configuration
update attempt failed
ROM bad checksum = address Expansion card improperly installed or
SAS port n hard disk drive
not found
Sector not found
Seek error
Seek operation failed
Shutdown failure
The amount of system
memory has changed
28
About Your System
Causes
The operating system cannot read
from the diskette or hard drive, the
system could not find a particular
sector on the disk, or the requested
sector is defective.
RAC cables not connected, or RAC
card installed in wrong expansion slot.
RAC card installed in wrong
expansion slot.
System unable to process Remote
Configuration request.
faulty.
SAS cables are not properly seated, or
drive missing.
Faulty diskette or hard drive.
Shutdown test failure.
Memory has been added or removed
or a memory module may be faulty.
Corrective Actions
Replace the diskette. Ensure that the
diskette and hard drive cables are
properly connected. See
"Troubleshooting a Diskette Drive" on
page 108, "Troubleshooting an Optical
Drive" on page 109, or "Troubleshooting
a Hard Drive" on page 110 for the
appropriate drive(s) installed in your
system.
Check that the RAC cables are
connected, and that the RAC card is
installed in the correct expansion slot.
See "RAC Card" on page 56.
Check that the RAC card is installed in
the correct expansion slot. See "RAC
Card" on page 56.
Retry Remote Configuration.
Reseat the expansion cards. Ensure that
all appropriate cables are securely
connected to the expansion cards. If the
problem persists, see "Troubleshooting
Expansion Cards" on page 113.
See "Troubleshooting a Hard Drive" on
page 110.
See "Troubleshooting a Diskette Drive"
on page 108 or "Troubleshooting a Hard
Drive" on page 110 for the appropriate
drive(s) installed in your system.
See "Troubleshooting System Memory"
on page 106.
If memory has been added or removed,
this message is informative and can be
ignored. If memory has not been added
or removed, check the SEL to determine
if single-bit or multi-bit errors were
detected and replace the faulty memory
module. See "Troubleshooting System
Memory" on page 106.