Advanced Topics in SPA9000 Administration
Remote Provisioning Features
NOTE
NOTE
SPA9000 Voice System Administration Guide
spa.bin is assumed, as in the following example: http://192.168.2.217/
admin/upgrade?tftp://192.168.2.251/spa.bin
Using the Resync URL
The
can be configured to automatically resynchronize its internal
SPA9000
configuration state to a remote profile periodically and on power up. The
automatic resyncs are controlled by configuring the desired profile URL into the
device.
The SPA resynchronizes only when it is idle.
SYNTAX:
http://spa-ip-addr/admin/resync?[[protocol://][server-
name[:port]]/profile-pathname]
EXAMPLE: http://192.168.2.217/admin/resync?tftp://
192.168.2.251/spaconf.cfg
•
If no parameter follows /resync?, the Profile Rule setting from the Provisioning
page is used.
•
If no protocol is specified, TFTP is assumed. If no server-name is specified, the
host that requests the URL is used as
•
If no port is specified, the default port is used (69 for TFTP, 80 for HTTP, and
443 for HTTPS).
•
The profile-path is the path to the new profile with which to resync.
Using the Reboot URL
You can use the Reboot URL to reboot the
The
reboots only when it is idle.
SPA9000
SYNTAX: http://spa-ip-addr/admin/reboot
EXAMPLE: http://192.168.2.217/admin/reboot
server-name
.
.
SPA9000
A
190