HP 201723-B21 - StorageWorks Modular SAN Array 1000 Hard Drive Maintenance And Service Manual page 53

Modular smart array
Hide thumbs Also See for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive:
Table of Contents

Advertisement

Message
306 FIRMWARE FLASH
STARTED
307 FIRMWARE FLASH
DONE
308 FIRMWARE FLASH
FAILED
309 EMU FLASH
STARTED
310 EMU FLASH DONE
311 EMU FLASH
FAILED
312 FIRMWARE FLASH
STARTED ON BOX #<n>
313 FIRMWARE FLASH
DONE ON BOX #<n>
314 FIRMWARE FLASH
FAILED ON BOX #<n>
400 STORAGE BOX
#<n> FAN OK
401 STORAGE BOX
#<n> FAN FAILED
Type
Description
Informational
The array controller in
the MSA has started the
firmware flash process.
Do not turn off power
to the system until it has
completed. This could take
several minutes.
Informational
The array controller in the
MSA has completed the
firmware flash process. It is
now safe to restart the MSA
and begin using the new
firmware. In dual-controller
configurations, the new
firmware is cloned onto the
other controller during the
startup routine.
Error
The array controller in
the MSA has failed the
firmware flash process.
Informational
The EMU has started the
firmware flash process.
Do not turn off the power
to the system until it has
completed. This could take
five minutes.
Informational
The EMU has completed the
firmware flash process. It is
now safe to turn off power
to the system.
Error
The EMU has failed the
firmware flash process.
Informational
A firmware flash operation
has started on an attached
storage enclosure.
Informational
A firmware flash operation
has completed on an
attached storage enclosure.
Error
A firmware flash operation
has failed on an attached
storage enclosure.
Informational
A fan in the specified
storage enclosure that
was previously marked as
failed or degraded is now
operating normally.
Error
A fan in the specified
storage enclosure has
failed. The MSA may
now be susceptible to
overheating if corrective
action is not taken.
Action
Attempt the flash process
again.
Should the issue persist,
contact HP support.
Attempt the flash process
again.
Should the issue persist,
contact HP support.
Restart the storage enclosure
to enable the new firmware.
Attempt the flash process
again.
Should the issue persist,
contact HP support.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced.
maintenance and service guide
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

353803-b22 - storageworks modular smart array 1000 san starterStorageworks 1000 - modular smart arrayStorageworks 1000

Table of Contents